MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ons/opz417

Медицинская библиотека · Operative neurosurgery (Hagerstown, Md.) · 2020

Identification of the Distal Dural Ring and Definition of Paraclinoid Aneurysms According to Bony Landmarks on 3-Dimensional Computed Tomography Angiography: A Cadaveric and Radiological Study.

Scerbak Jelena, Lapteva Ona, Sahin Omer S, Ksanas Ugnius, Barkauskiene Alina, Lengvenis Givi, Ozaydin Burak, Cikla Ulas, Baskaya Mustafa K

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Determining if paraclinoid aneurysms are intradural or extradural is critical for surgical planning.

OBJECTIVE

To create an easily reproducible diagnostic method based on bony anatomy that precisely locates the distal dural ring (DDR) to determine the position of paraclinoid aneurysms as intradural, transitional, or extradural.

METHODS

Bilateral anatomic dissections of 10 cadaveric heads (20 sides) were performed to evaluate DDR anatomy. We observed a plane that reflects the position of the DDR passes through 4 bony landmarks: 1) The anterior clinoid-internal carotid artery intersection, 2) the optic strut, 3) the optico-carotid elevation, and 4) the base of the posterior clinoid process. This landmark-based plane can thus define the location of the DDR using 3-dimensional computed tomography angiography (CTA). This was confirmed in 27 surgical patients with intradural/transitional aneurysms and 7 patients with extradural aneurysms confirmed with magnetic resonance imaging (MRI). The DDR plane method easily classified aneurysm locations as intradural (above the DDR plane), extradural (below the DDR plane), or transitional (the DDR plane crosses the aneurysm). The aneurysm's location was subsequently confirmed intraoperatively or with MRI.

RESULTS

The DDR plane method determined if paraclinoid aneurysms were intradural, transitional, or extradural in all 34 cases examined. The visibility of the anatomic features that define the DDR plane was also verified in 82% to 89% of CTA images from 100 patients.

CONCLUSION

The DDR plane method provides a useful diagnostic tool to evaluate the position of the DDR and determine the anatomic location of paraclinoid aneurysms.

Для цитирования: Scerbak Jelena, Lapteva Ona, Sahin Omer S, Ksanas Ugnius, Barkauskiene Alina, Lengvenis Givi, Ozaydin Burak, Cikla Ulas, Baskaya Mustafa K. Identification of the Distal Dural Ring and Definition of Paraclinoid Aneurysms According to Bony Landmarks on 3-Dimensional Computed Tomography Angiography: A Cadaveric and Radiological Study.. Operative neurosurgery (Hagerstown, Md.). 2020. DOI: 10.1093/ons/opz417.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.