MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ccm.0000000000004569

Медицинская библиотека · Critical care medicine · 2020

Late Ventilator-Induced Diaphragmatic Dysfunction After Extubation.

Dridi Haikel, Jung Boris, Yehya Mohamad, Daurat Aurelien, Reiken Steven, Moreau Johan, Marks Andrew R, Matecki Stefan, Lacampagne Alain, Jaber Samir

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Mechanical ventilation is associated with primary diaphragmatic dysfunction, also termed ventilator-induced diaphragmatic dysfunction. Studies evaluating diaphragmatic function recovery after extubation are lacking. We evaluated early and late recoveries from ventilator-induced diaphragmatic dysfunction in a mouse model.

DESIGN

Experimental randomized study.

SETTING

Research laboratory.

SUBJECTS: C57/BL6 mice.

INTERVENTIONS: Six groups of C57/BL6 mice. Mice were ventilated for 6 hours and then euthanatized immediately (n = 18), or 1 (n = 18) or 10 days after extubation with (n = 5) and without S107 (n = 16) treatment. Mice euthanatized immediately after 6 hours of anesthesia (n = 15) or after 6 hours of anesthesia and 10 days of recovery (n = 5) served as controls.

MEASUREMENTS AND MAIN

RESULTS

For each group, diaphragm force production, posttranslational modification of ryanodine receptor, oxidative stress, proteolysis, and cross-sectional areas were evaluated. After 6 hours of mechanical ventilation, diaphragm force production was decreased by 25-30%, restored to the control levels 1 day after extubation, and secondarily decreased by 20% 10 days after extubation compared with controls. Ryanodine receptor was protein kinase A-hyperphosphorylated, S-nitrosylated, oxidized, and depleted of its stabilizing subunit calstabin-1 6 hours after the onset of the mechanical ventilation, 1 and 10 days after extubation. Post extubation treatment with S107, a Rycal drug that stabilizes the ryanodine complex, did reverse the loss of diaphragmatic force associated with mechanical ventilation. Total protein oxidation was restored to the control levels 1 day after extubation. Markers of proteolysis including calpain 1 and calpain 2 remained activated 10 days after extubation without significant changes in cross-sectional areas.

CONCLUSIONS

We report that mechanical ventilation is associated with a late diaphragmatic dysfunction related to a structural alteration of the ryanodine complex that is reversed with the S107 treatment.

Для цитирования: Dridi Haikel, Jung Boris, Yehya Mohamad, Daurat Aurelien, Reiken Steven, Moreau Johan, Marks Andrew R, Matecki Stefan, Lacampagne Alain, Jaber Samir. Late Ventilator-Induced Diaphragmatic Dysfunction After Extubation.. Critical care medicine. 2020. DOI: 10.1097/ccm.0000000000004569.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.