Crosslinked All-Femtosecond Laser-Cut Corneal Allogenic Intracorneal Ring Segments (AFXL CAIRSs): Pilot Ex Vivo Study and Report of First Two Cases Performed in Italy.

Mazzotta Cosimo, Zagari Marco, Bona Giulia, Ponzin Diego, Awwad Shady T, Torres-Netto Emilio A, Hafezi Farhad, Jacob Soosan

СтатьяПеревод пока не подготовлен

Аннотация

Objectives

This pilot ex vivo study and first clinical experience in Italy evaluate the impact of using pre-implantation crosslinking on all-femtosecond laser-cut corneal allogenic intracorneal ring segments (AFXL CAIRSs).

Methods

Six human donor eye-bank corneas were used for this preclinical ex vivo human study. Three donor (D) corneas were used for AFXL CAIRSs. First, they were prepared with an IntraLase™ femtosecond laser (Johnson & Johnson, New Brunswick, NJ, USA). The allogenic tissue rings were crosslinked before implantation with Riboflavin-UV-A accelerated crosslinking protocol (ACXL) with a 0.1% HPMC Riboflavin isotonic solution (Vibex Rapid, Glaukos-Avedro, Burlington, MA, USA) and a new KXL UV-A emitter (Glaukos-Avedro, USA). Three corneas were used as recipients (Rs) of the AFXL CAIRSs. After completing the ex vivo phase, IRB approval and signing a specific informed consent, the first two Italian patients were treated. A single ACXL CAIRS was implanted in a 51-year-old male with 53.53 D K steep, 363 μm minimum corneal thickness (MCT) and a double ACXL CAIRS was implanted in a 46-year-old male patient with 58.30 D K steep, 443 μm MCT. The longest follow-up was at three months.

Results

Crosslinking of the segments enhanced tissue stiffness and grip, facilitating manipulation and CAIRS insertion into the recipient tunnels, and the yellowish color of the crosslinked segments improved visibility. The segment's thickness and volume remained unaltered during the follow-up. Both patients improved UDVA and BSCVA. K steep and High-Order Aberrations (HOAs) were reduced and MCT increased.

Conclusions

Pre-implantation ACXL facilitated CAIRS insertion preserving dimensions and volume during the follow-up, rendering this important step a promising candidate in method standardization. Functional data and MCT improved significantly without adverse events.

Для цитирования: Mazzotta Cosimo, Zagari Marco, Bona Giulia, Ponzin Diego, Awwad Shady T, Torres-Netto Emilio A, Hafezi Farhad, Jacob Soosan. Crosslinked All-Femtosecond Laser-Cut Corneal Allogenic Intracorneal Ring Segments (AFXL CAIRSs): Pilot Ex Vivo Study and Report of First Two Cases Performed in Italy.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13195771.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.