MedElevator Войти в исследования
← Поиск публикаций

DOI 10.62347/ozen2943

Медицинская библиотека · American journal of translational research · 2024

Effect of corneal diameter on preoperative screening results for corneal refractive surgery.

Zhang Lina, Liu Qinglin, Shao Hui, Ni Lisha, Wang Kai, Ma Liwei, Huang Wu

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: To investigate the impact of different corneal diameters on corneal morphology and biomechanical outcome during preoperative screening for corneal refractive surgery.

METHODS

A retrospective analysis was conducted on 300 patients who underwent corneal refractive surgery at Eye and ENT Hospital, Fudan University between October 2023 and December 2023. All patients had no history of keratoconus or previous corneal surgery. Patients were categorized into two groups based on corneal topography measurements: (1) normal corneal diameter group (n=159), those with corneal diameter ranging from 11.5 mm to 12.0 mm; (2) abnormal corneal diameter group (n=141), those with corneal diameter smaller than 10.0 mm or larger than 12.5 mm. Corneal thickness, morphologic data, and biomechanical data were measured using Pentacam corneal topography. Correlation analysis was conducted to explore the relationship between corneal diameter and various corneal topography and biomechanical data.

RESULTS

Significant differences were observed in corneal topography data including BFSf (F=43.21), BFSb (F=30.24), Df (F=15.32), Dp (F=32.36), Da (F=9.66), D (F=58.36), PPIavg (F=32.64), and ARTmax (F=12.06) between the groups (P<0.05). Additionally, BFSf, BFSb, Db, Dp, D, and PPIavg exhibited statistically significant differences between any two groups (P<0.05). Significant differences were also found in Df, Da, and ARTmax between small and large corneas, as well as between normal-sized and large corneas (P<0.05). Correlation analysis indicated negative correlations between corneal diameter and A1V (r=-0.12), HCdArcLength (r=-0.17), CBI (r=-0.27), bIOP (r=-0.13), Df (r=-0.025), PPIavg (r=-0.028), and TBI (r=-0.27). Conversely, BFSf (r=0.009), BFSb (r=0.001), PD (r=0.15), and ARTH (r=0.37) displayed positive correlations with corneal diameter.

CONCLUSIONS

Corneal diameter significantly affects preoperative screening for corneal refractive surgery. Smaller corneal diameters exhibit a greater influence on the corneal topography BAD analysis system.

Для цитирования: Zhang Lina, Liu Qinglin, Shao Hui, Ni Lisha, Wang Kai, Ma Liwei, Huang Wu. Effect of corneal diameter on preoperative screening results for corneal refractive surgery.. American journal of translational research. 2024. DOI: 10.62347/ozen2943.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.