PURPOSE: Full-thickness macular hole associated with diabetic macular oedema is a rare feature and its pathogenesis remains incompletely elucidated. We report the occurrence of a full-thickness macular hole, documented with optical coherence tomography (OCT), in a patient with diabetic cystoid macular oedema treated by intravitreal triamcinolone injections.

CASE REPORT: A 48-year-old woman with refractory diabetic cystoid macular oedema underwent successive intravitreal triamcinolone injections, which were followed by a progressive thinning of the neurosensory retina at the fovea, and then by a full-thickness macular hole, associated with a perifoveal posterior hyaloid detachment, visible on OCT. During pars plana vitrectomy, a thin epiretinal macular membrane was diagnosed and removed.

DISCUSSION: Pathogenesis of the present full-thickness macular hole associated with diabetic macular oedema is different from that of idiopathic macular holes because anteroposterior vitreous tractions were not involved in its formation. Recurrent intravitreal triamcinolone injections may have had an indirect role in the development of the macular hole, by favouring the rupture of distended Muller cells and intraretinal pseudocysts.

Для цитирования: Lecleire-Collet Amélie, Offret Olivier, Gaucher David, Audren François, Haouchine Belkacem, Massin Pascale. Full-thickness macular hole in a patient with diabetic cystoid macular oedema treated by intravitreal triamcinolone injections.. Acta ophthalmologica Scandinavica. 2007. DOI: 10.1111/j.1600-0420.2007.00925.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.