MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-005-0112-6

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2005

Detection of paravascular retinal cysts before using OCT in a highly myopic patient.

Ohno-Matsui Kyoko, Hayashi Kengo, Tokoro Takashi, Mochizuki Manabu

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We describe a case of high myopia who developed paravascular retinal rarefaction generated by vitreoretinal adhesion on retinal vessels detected using optical coherence tomography (OCT).

METHODS

A 31-year-old man received a regular ophthalmologic examination for high myopia including detailed fundus examination and OCT.

RESULTS

Detailed fundus examination revealed retinal rarefaction and fissure-like findings alongside the superior temporal retinal artery and vein in the right eye. OCT images revealed vitreoretinal adhesions on the retinal artery and a paravascular cystoid space in the inner retina. There was no retinal detachment. The axial length had increased by 1.50 mm over 15 years.

CONCLUSION

Paravascular retinal rarefaction as well as pseudohole formation caused by vitreoretinal adhesion on retinal vessels was detected in this patient using OCT. OCT might be useful to detect early-stage retinal pathologies caused by paravascular vitreoretinal traction in highly myopic patients.

Для цитирования: Ohno-Matsui Kyoko, Hayashi Kengo, Tokoro Takashi, Mochizuki Manabu. Detection of paravascular retinal cysts before using OCT in a highly myopic patient.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2005. DOI: 10.1007/s00417-005-0112-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.