PURPOSE: To report a case of idiopathic vitreomacular traction syndrome with preoperative and postoperative evaluation by optical coherence tomography.

DESIGN

Interventional case report.

METHODS

A 62-year-old woman presented with blurred vision in the left eye because of idiopathic vitreomacular traction syndrome, and she underwent a pars plana vitrectomy. Optical coherence tomography was performed before and after surgery.

RESULTS

Preoperative optical coherence tomography, right eye, revealed residual adhesion of incomplete posterior vitreous detachment and edematous, thickened outer retina in the macula. A successful vitrectomy relieved vitreoretinal traction with nearly complete resolution of cystoid macular edema within 1 month after surgery, followed in subsequent months by gradual foveal depression resembling a lamellar macular hole. Resolution of subretinal serous fluid was delayed with complete disappearance, some 12 months after surgery, which correlated with a gradual improvement in visual acuity.

CONCLUSION

Optical coherence tomography provides a sensitive anatomical evaluation of vitreomacular traction syndrome. Reorganization of retinal tissue after surgical intervention for vitreoretinal traction may be slower than is apparent from conventional examinations.

Для цитирования: Uchino E, Uemura A, Doi N, Ohba N. Postsurgical evaluation of idiopathic vitreomacular traction syndrome by optical coherence tomography.. American journal of ophthalmology. 2001. DOI: 10.1016/s0002-9394(00)00957-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.