Krasniqi Lytfi, Terkelsen Christian Juhl, Nissen Henrik, Freeman Philip, Frederiksen Christian Alcaraz, Vase Henrik, Hejlesen Kristian, Fur Christian Byskov, Thim Troels, Eftekhari Ashkan, Uttenthal Frederik, Ellert Julia, Borg Mogensen Nils Sofus, Haujir Amal, Christiansen Evald Høj, Dahl Jordi Sanchez

СтатьяСравнительное исследованиеМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to study the impact of flow status on effective orifice area (EOA) in patients treated with the balloon-expandable Myval and Sapien transcatheter heart valves (THVs).

METHODS

We collected the core laboratory-measured EOA, mean and peak gradients, Doppler velocity index (DVI), and stroke volume index (SVi) from the 30-day echocardiograms in patients treated with the balloon-expandable Myval and Sapien THVs in the COMPARE-TAVI 1 trial. Patients were stratified according to flow into low flow (SVi <35 mL/m2), normal flow (SVi 35-50 mL/m2), and high flow (SVi >50 mL/m2).

RESULTS

A total of 1,031 patients were included in COMPARE-TAVI 1. Myval THVs (20.0-32.0 mm) exhibited overall higher mean EOA and lower mean gradients (1.99 ± 0.55 cm2, 9.46 ± 3.84 mm Hg) compared to Sapien THVs (20-29 mm; 1.81 ± 0.56 cm2, 11.47 ± 4.47 mm Hg). Compared to normal-flow patients, low-flow patients exhibited smaller EOA (P < .001) and lower DVI (P < .001) in all valve sizes irrespective of THV platform, while high-flow patients had larger EOA (P < .001) and higher DVI (P < .001). Female sex was associated with lower stroke volume, resulting in lower mean and peak gradients independent of valve size and platform (P < .001).

CONCLUSION

The study indicates that EOA may be underestimated after TAVI in patients with low-flow status, which can impact the assessment of prosthesis-patient mismatch.

Для цитирования: Krasniqi Lytfi, Terkelsen Christian Juhl, Nissen Henrik, Freeman Philip, Frederiksen Christian Alcaraz, Vase Henrik, Hejlesen Kristian, Fur Christian Byskov, Thim Troels, Eftekhari Ashkan, Uttenthal Frederik, Ellert Julia, Borg Mogensen Nils Sofus, Haujir Amal, Christiansen Evald Høj, Dahl Jordi Sanchez. Impact of Flow Status on Effective Orifice Area in Transcatheter Heart Valves: A COMPARE-TAVI 1 Substudy.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2025. DOI: 10.1016/j.echo.2025.09.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.