MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00392-025-02744-y

Медицинская библиотека · Clinical research in cardiology : official journal of the German Cardiac Society · 2025

Safety and effectiveness of oscillatory whole-body vibration training on exercise capacity and physical performance in aortic valve stenosis patients prior to transcatheter aortic valve implantation: a randomized clinical trial.

Klaus Johannes, Gerhardt Felix, Nienaber Stephan, Mauri Victor, Möllenhoff Kathrin, Nies Richard, Kuhn Elmar, Gerfer Stephen, Djordjevic Ilija, Lee Samuel, Guthoff Henning, Iliadis Christos, Baldus Stephan, Hohmann Christopher, Adam Matti, Wienemann Hendrik

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Exercise training is generally discouraged in patients with severe symptomatic aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI) due to safety concerns. However, whole-body vibration (WBV) exercise could offer a novel approach to improve exercise capacity and quality of life, though its effects remain unclear in this population.

METHODS

Thirty patients with AS scheduled for TAVI were prospectively and randomly assigned to either the WBV group (12 sessions, 30 min each over 4 weeks) or a control group. Assessments of cardiopulmonary exercise testing (CPET), 6-min walking distance (6MWD) and health-related quality of life (HRQoL) questionnaires were conducted at baseline (V1), one day before TAVI (V2) and at short-term follow-up (V3). WBV was conducted between V1 and V2.

RESULTS

For the analysis at V1 and V2 16 patients in the WBV group and 14 in the control group were included. Mean age was 79.7 ± 5.22 years, with a mean aortic valve area of 0.75 ± 0.21 cm2. Peak V'O2 increased by 0.3 mL*min-1*kg-1 in the WBV group versus a decrease of - 1.4 mL*min-1*kg-1 in the control group (difference, 1.7 mL*min-1*kg-1; 95% CI, [0.2 to 3.2], p = 0.03). Peak power improved by 5.1 W in the WBV group compared to a decline of - 4.5 W in the control group (difference, 9.6 W; 95% CI, [2.1 to 17.1], p = 0.01). The WBV group also showed a non-significant improvement in 6MWD (34 m vs. - 8 m in the control group; difference, 42 m; 95% CI, [-10 to 93], p = 0.11). No serious adverse events occurred in the WBV group.

CONCLUSION

This pilot study demonstrated that a WBV exercise program is feasible, safe, and showed potential to preserve exercise capacity as well as physical performance in AS patients scheduled for TAVI.

Для цитирования: Klaus Johannes, Gerhardt Felix, Nienaber Stephan, Mauri Victor, Möllenhoff Kathrin, Nies Richard, Kuhn Elmar, Gerfer Stephen, Djordjevic Ilija, Lee Samuel, Guthoff Henning, Iliadis Christos, Baldus Stephan, Hohmann Christopher, Adam Matti, Wienemann Hendrik. Safety and effectiveness of oscillatory whole-body vibration training on exercise capacity and physical performance in aortic valve stenosis patients prior to transcatheter aortic valve implantation: a randomized clinical trial.. Clinical research in cardiology : official journal of the German Cardiac Society. 2025. DOI: 10.1007/s00392-025-02744-y.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.