MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12886-021-01871-0

Медицинская библиотека · BMC ophthalmology · 2021

Factors associated with ocular surface epithelial damage in patients with primary Sjögren's syndrome.

Kim Ji Eun, Kim Na Rae, Chin Hee Seung, Seo Kyoung Yul, Kim Tae-Im, Jung Ji Won

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of this study was to evaluate the effects of systemic parameters, laboratory findings, oral parameters, and other ocular surface parameters on ocular surface epithelial damage in patients with primary Sjögren's syndrome (pSS).

METHODS

A total of 82 dry eye disease (DED) patients with pSS were enrolled in this study. Ocular surface epithelial damage was measured by ocular staining score (OSS). Systemic parameters, laboratory findings including serologic markers, oral parameters, and other ocular surface parameters were collected. Other ocular surface parameter assessments such as the Schirmer's test, fluorescein tear breakup time, meibomian gland examinations, noninvasive keratographic tear film break-up time measurements using the Keratograph® 5 M were performed, and the Ocular Surface Disease Index was determined.

RESULTS

In a multivariate analysis, decreased age and increased duration of pSS were significantly related to increased logarithm-transformed OSS (β = -0.011, P = 0.043 and β = 0.003, P = 0.008). Among the ocular surface parameters, decreased fluorescein tear breakup time and increased MGD grade were significantly associated with increased logarithm-transformed OSS (β = -0.183, P < 0.001 and β = 0.192, P = 0.049).

CONCLUSIONS

Ocular surface epithelial damage in patients with pSS was associated with young age, long duration of disease, unstable tear film, and decreased meibomian gland function.

Для цитирования: Kim Ji Eun, Kim Na Rae, Chin Hee Seung, Seo Kyoung Yul, Kim Tae-Im, Jung Ji Won. Factors associated with ocular surface epithelial damage in patients with primary Sjögren's syndrome.. BMC ophthalmology. 2021. DOI: 10.1186/s12886-021-01871-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.