MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-020-05044-5

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2021

Characteristics of dry eye patients with thick tear film lipid layers evaluated by a LipiView II interferometer.

Lee Yunjin, Hyon Joon Young, Jeon Hyun Sun

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the characteristics of eyes with dry eye disease (DED) whose lipid layer thickness (LLT) measured 100 nm on a LipiView II interferometer and compare the DED parameters of them to those with LLT below 100 nm.

METHODS

A total of 201 eyes of 102 enrolled DED patients (mean age 56.4 ± 11.8 years) were classified into 3 groups according to their average LLT; < 60 nm as thin-LLT (n = 49), 60-99 nm as normal-LLT (n = 77), and 100 nm as thick-LLT (n = 75). LLT, meiboscore, Schirmer I test, tear film break-up time (TBUT), ocular surface staining (OSS), and ocular surface disease index (OSDI) were assessed.

RESULTS

The OSS and TBUT were significantly worse in the thick-LLT group than in the normal-LLT group (p = 0.020, and p = 0.028, respectively). The OSDI was significantly higher in the thick-LLT group than in the thin-LLT group (p = 0.006). However, the meiboscore was not different among the three groups (p = 0.33). Age, OSS, and OSDI showed a positive correlation with LLT (r = 0.16, p = 0.023; r = 0.213, p = 0.003; and r = 0.338, p = 0.001, respectively). In sensitivity analyses, eyes with corneal erosions had a significantly higher average LLT (p = 0.015), higher OSDI (p = 0.009), shorter TBUT (p < 0.001), and shorter Schirmer I value (p = 0.024) than those with clear corneas.

CONCLUSION

The average LLT of eyes with corneal erosions was thicker than those without erosions, suggesting that the LLT of 100 nm in the eyes with corneal erosions should not be regarded as a stable physiologic condition. Cautious interpretation of LLT along with other dry eye parameters is required.

Для цитирования: Lee Yunjin, Hyon Joon Young, Jeon Hyun Sun. Characteristics of dry eye patients with thick tear film lipid layers evaluated by a LipiView II interferometer.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2021. DOI: 10.1007/s00417-020-05044-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.