MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2471/blt.15.158741

Медицинская библиотека · Bulletin of the World Health Organization · 2016

Accuracy of point-of-care testing for circulatory cathodic antigen in the detection of schistosome infection: systematic review and meta-analysis.

Danso-Appiah Anthony, Minton Jonathan, Boamah Daniel, Otchere Joseph, Asmah Richard H, Rodgers Mark, Bosompem Kwabena M, Eusebi Paolo, De Vlas Sake J

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess the accuracy of point-of-care testing for circulatory cathodic antigen in the diagnosis of schistosome infection.

METHODS

We searched MEDLINE, EMBASE, LILACS and other bibliographic databases for studies published until 30 September 2015 that described circulatory cathodic antigen testing compared against one to three Kato-Katz tests per subject - for Schistosoma mansoni - or the filtration of one 10-ml urine sample per subject - for S. haematobium. We extracted the numbers of true positives, false positives, true negatives and false negatives for the antigen testing and performed meta-analyses using a bivariate hierarchical regression model.

FINDINGS: Twenty-six studies published between 1994 and 2014 met the inclusion criteria. In the detection of S. mansoni, a single antigen test gave a pooled sensitivity of 0.90 (95% confidence interval, CI: 0.84-0.94) and a pooled specificity of 0.56 (95% CI: 0.39-0.71; n = 7) when compared against a single Kato-Katz test. The corresponding values from comparisons with two to three Kato-Katz tests per subject were 0.85 (95% CI: 0.80-0.88) and 0.66 (95% CI: 0.53-0.76; n = 14), respectively. There appeared to be no advantage in using three antigen tests per subject instead of one. When compared against the results of urine filtration, antigen testing for S. haematobium showed poor sensitivity and poor specificity. The performance of antigen testing was better in areas of high endemicity than in settings with low endemicity.

CONCLUSION

Antigen testing may represent an effective tool for monitoring programmes for the control of S. mansoni.

Для цитирования: Danso-Appiah Anthony, Minton Jonathan, Boamah Daniel, Otchere Joseph, Asmah Richard H, Rodgers Mark, Bosompem Kwabena M, Eusebi Paolo, De Vlas Sake J. Accuracy of point-of-care testing for circulatory cathodic antigen in the detection of schistosome infection: systematic review and meta-analysis.. Bulletin of the World Health Organization. 2016. DOI: 10.2471/blt.15.158741.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.