MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/euje.2001.0110

Медицинская библиотека · European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology · 2002

Left atrial appendage function in patients with mitral stenosis in sinus rhythm.

Gölbaşi Z, Ciçek D, Canbay A, Uçar O, Bayol H, Aydogdu S

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Left atrial appendage thrombi are believed to be the source of embolism in patients with rheumatic mitral stenosis in atrial fibrillation. There are a few studies which search the effects of left atrial appendage dysfunction in patients with mitral stenosis in sinus rhythm.

METHODS AND

RESULTS

Left atrial appendage function and flow patterns in 41 patients with rheumatic mitral stenosis in sinus rhythm and 11 healthy subjects were studied by transoesophageal echocardiography. Left atrial appendage flow profiles were recorded within the proximal third of the appendage. The left atrial appendage ejection fraction was expressed as (maximal area of appendage minimal area of appendage)/maximal area of appendage. In addition, two-dimensional imaging was used to determine the presence of spontaneous echocardiographic contrast and thrombus formation. Patients with mitral stenosis in sinus rhythm had significantly decreased left atrial appendage emptying and filling velocities compared to controls (0.40+/-0.15m/s vs 0.82+/-0.19 m/s and 0.42+/-0.21 m/s vs 0.68+/-0.28, respectively, P<0.001 and P<0.05). Compared with the control subjects, patients with mitral stenosis had significantly greater maximal area of the appendage and had reduced left atrial appendage ejection fraction (5.3+/-2.2 cm(2) vs 2.4+/-0.5 cm(2) and 50+/-16% vs 70+/-7%, respectively, P<0.001 and P<0.05). Of the patients with mitral stenosis in sinus rhythm, seven patients had spontaneous echocardiographic contrast and one of these had left atrial appendage thrombus. Compared with patients without spontaneous echocardiographic contrast, patients with spontaneous echocardiographic contrast had decreased left atrial appendage ejection fraction (33+/-21% vs 54+/-13%,P <0.01). One of the patients with mitral stenosis had central retinal artery occlusion, but thrombus was not observed in left atrial appendage.

CONCLUSION

The study found that left atrial appendage dysfunction may occur in patients with mitral stenosis in sinus rhythm.

Для цитирования: Gölbaşi Z, Ciçek D, Canbay A, Uçar O, Bayol H, Aydogdu S. Left atrial appendage function in patients with mitral stenosis in sinus rhythm.. European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology. 2002. DOI: 10.1053/euje.2001.0110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.