MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0161-6420(01)01011-9

Медицинская библиотека · Ophthalmology · 2002

Embolic central retinal artery occlusion detected by orbital color Doppler imaging.

Foroozan Rod, Savino Peter J, Sergott Robert C

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To describe the detection of emboli to the retrobulbar circulation using orbital color Doppler imaging in patients with central retinal artery occlusions (CRAO) without visible retinal emboli.

DESIGN

Noncomparative, retrospective, observational case series.

PATIENTS AND

METHODS

Twenty-nine patients with CRAO, without funduscopic evidence of embolic material within the retinal arterioles, underwent neuroophthalmic examination and evaluation with orbital color Doppler imaging.

MAIN OUTCOME MEASURES: The detection of retrobulbar plaques using orbital color Doppler imaging.

RESULTS

Nine of 29 (31%) patients with CRAO demonstrated hyperechoic retrobulbar plaques. All nine patients had visual acuity of counting fingers or worse at presentation. Six of the nine patients (67%) had a history of hypertension, and seven (78%) had coronary artery disease as vascular risk factors for arterial occlusive disease. Two of the nine patients (22%) subsequently died from cardiac-related events.

CONCLUSIONS

This study demonstrates that orbital color Doppler imaging is an important diagnostic procedure for establishing embolism as the cause of CRAO when no emboli are visible in the retinal circulation. This noninvasive technology enables prompt differentiation of embolic disease from arterial occlusion caused by intrinsic atherosclerosis, vasospasm, or vasculitis from giant cell arteritis. Recognition of emboli has important management implications for these patients.

Для цитирования: Foroozan Rod, Savino Peter J, Sergott Robert C. Embolic central retinal artery occlusion detected by orbital color Doppler imaging.. Ophthalmology. 2002. DOI: 10.1016/s0161-6420(01)01011-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.