MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2018.02.031

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2018

Iliac Vein Stent Placement: Acute Venographic Changes and Relevance to Venous Biomechanics.

Al-Hakim Ramsey A, Kaufman John A, Farsad Khashayar

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe acute venographic changes of external iliac vein (EIV) after ipsilateral common iliac vein (CIV) stent placement.

MATERIALS AND

METHODS

Retrospective review was performed of 17 cases with placement of a single CIV stent. Central CIV stent diameter and minimal ipsilateral EIV diameter were measured on venogram; vein diameter was measured at the same 2 anatomic locations on venogram obtained before intervention. Relative CIV diameter increase was defined as the ratio of change in central CIV diameter after stent placement to CIV diameter before intervention. Relative EIV diameter reduction was defined as the ratio of change in diameter of EIV after stent deployment in CIV to EIV diameter before intervention. Diameters before and after intervention were compared using a 2-tailed, paired sample t test. Pearson coefficient was calculated for correlations.

RESULTS

There was a significant reduction of EIV diameter after ipsilateral CIV stent placement compared with before stent placement (mean 9.3 mm ± 3.1 vs 11.9 mm ± 3.8; P < .01); mean decrease in EIV diameter was 21.7% ± 15.8. There was a correlation between relative CIV diameter increase and relative EIV diameter reduction (r = .8917).

CONCLUSIONS

Significant venographic narrowing of the EIV occurs after placement of an adjacent CIV stent, and the degree of narrowing is associated with the relative increase in CIV diameter. These findings may be explained by the inherent anisotropic elasticity of veins. Further study is warranted to guide future venous interventions.

Для цитирования: Al-Hakim Ramsey A, Kaufman John A, Farsad Khashayar. Iliac Vein Stent Placement: Acute Venographic Changes and Relevance to Venous Biomechanics.. Journal of vascular and interventional radiology : JVIR. 2018. DOI: 10.1016/j.jvir.2018.02.031.