OBJECTIVE

The aim of the present study was to investigate the mitral annulus (MA) geometry and dynamic motion changes in patients with aortic regurgitation (AR) before and after aortic valve replacement (AVR). Moreover, the difference in the effect of the type of prosthetic aortic valve on MA was compared.

DESIGN

Prospective observational study.

SETTING

Cardiac operating room at a single hospital.

PARTICIPANTS

Eighty-two patients with isolated moderate-to-severe AR who underwent AVR. Forty patients with normal valves were enrolled as controls.

INTERVENTIONS: None.

MEASUREMENTS AND MAIN

RESULTS

The MA geometry and dynamic motion throughout the cardiac cycle were evaluated semiautomatically by three-dimensional transesophageal echocardiography. The severity of functional mitral regurgitation was intraoperatively evaluated. All patients were divided into 2 groups depending on the type of prosthetic valve (mechanical valve and bioprosthetic valve groups). Before AVR, compared with the control group without AR, the AR group demonstrated larger MA dimensions and the MA geometry was flatter. The contraction fraction of the MA area, perimeter, and height during the whole cardiac cycle were larger in the AR group (p < 0.05 for all). After AVR, most MA geometric and dynamic parameters decreased and functional mitral regurgitation also improved. In the postoperative subset analyses, the mechanical valve group showed a larger contraction fraction of the MA area and perimeter than the bioprosthetic valve group (p < 0.05 for both).

CONCLUSIONS

The MA geometry and dynamic motion changed markedly in patients with AR. These spatial and dynamic changes were restored to a certain extent after surgical correction of the aortic valve. However, the effects produced by mechanical and bioprosthetic valves on MA were different.

Для цитирования: Meng Qinglong, Wan Linyuan, Duan Fujian, Wang Dandan, Tao Jia, Wang Hao. Mitral Annulus Geometry and Dynamic Motion Changes in Patients With Aortic Regurgitation: A Three-Dimensional Transesophageal Echocardiographic Study.. Journal of cardiothoracic and vascular anesthesia. 2022. DOI: 10.1053/j.jvca.2022.05.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.