MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00380-022-02111-1

Медицинская библиотека · Heart and vessels · 2022

Impact of progressive aortic regurgitation on outcomes after left ventricular assist device implantation.

Gasparovic Hrvoje, Jakus Nina, Brugts Jasper J, Pouleur Anne-Catherine, Timmermans Philippe, Rubiś Pawel, Gaizauskas Edvinas, Van Craenenbroeck Emeline M, Barge-Caballero Eduardo, Grundmann Sebastian, Paolillo Stefania, D'Amario Domenico, Braun Oscar Ö, Meyns Bart, Droogne Walter, Wierzbicki Karol, Holcman Katarzyna, Planinc Ivo, Lovric Daniel, Flammer Andreas J, Petricevic Mate, Biocina Bojan, Lund Lars H, Milicic Davor, Ruschitzka Frank, Cikes Maja

СтатьяПеревод пока не подготовлен

Аннотация

Aortic regurgitation (AR) following continuous flow left ventricular assist device implantation (cf-LVAD) may adversely impact outcomes. We aimed to assess the incidence and impact of progressive AR after cf-LVAD on prognosis, biomarkers, functional capacity and echocardiographic findings. In an analysis of the PCHF-VAD database encompassing 12 European heart failure centers, patients were dichotomized according to the progression of AR following LVAD implantation. Patients with de-novo AR or AR progression (AR_1) were compared to patients without worsening AR (AR_0). Among 396 patients (mean age 53 ± 12 years, 82% male), 153 (39%) experienced progression of AR over a median of 1.4 years on LVAD support. Before LVAD implantation, AR_1 patients were less frequently diabetic, had lower body mass indices and higher baseline NT-proBNP values. Progressive AR did not adversely impact mortality (26% in both groups, HR 0.91 [95% CI 0.61-1.36]; P = 0.65). No intergroup variability was observed in NT-proBNP values and 6-minute walk test results at index hospitalization discharge and at 6-month follow-up. However, AR_1 patients were more likely to remain in NYHA class III and had worse right ventricular function at 6-month follow-up. Lack of aortic valve opening was related to de-novo or worsening AR (P < 0.001), irrespective of systolic blood pressure (P = 0.67). Patients commonly experience de-novo or worsening AR when exposed to continuous flow of contemporary LVADs. While reducing effective forward flow, worsening AR did not influence survival. However, less complete functional recovery and worse RV performance among AR_1 patients were observed. Lack of aortic valve opening was associated with progressive AR.

Для цитирования: Gasparovic Hrvoje, Jakus Nina, Brugts Jasper J, Pouleur Anne-Catherine, Timmermans Philippe, Rubiś Pawel, Gaizauskas Edvinas, Van Craenenbroeck Emeline M, Barge-Caballero Eduardo, Grundmann Sebastian, Paolillo Stefania, D'Amario Domenico, Braun Oscar Ö, Meyns Bart, Droogne Walter, Wierzbicki Karol, Holcman Katarzyna, Planinc Ivo, Lovric Daniel, Flammer Andreas J, Petricevic Mate, Biocina Bojan, Lund Lars H, Milicic Davor, Ruschitzka Frank, Cikes Maja. Impact of progressive aortic regurgitation on outcomes after left ventricular assist device implantation.. Heart and vessels. 2022. DOI: 10.1007/s00380-022-02111-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.