MedElevator Войти в исследования
← Поиск публикаций

DOI 10.25270/jic/21.00212

Медицинская библиотека · The Journal of invasive cardiology · 2022

Transcatheter Aortic Valve Replacement for Severe Aortic Regurgitation in Patients With a Left Ventricular Assist Device.

Dhillon Ashwat S, Jones Brandon M, Hodson Robert W, Korngold Ethan C

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

There are limited invasive treatment options for patients with end-stage heart failure and left ventricular assist device (LVAD) who develop severe aortic valve regurgitation (AR). One option for such patients is transcatheter aortic valve replacement (TAVR). There are limited data on outcomes of patients with LVAD who receive TAVR for severe AR. We present a series of 4 consecutive patients with LVAD who underwent TAVR for severe AR.

METHODS AND

RESULTS

This is a retrospective chart review of 4 consecutive patients with LVAD who underwent TAVR for severe AR. All 4 patients underwent TAVR with a 34-mm self-expanding valve (Medtronic). One patient received a 29-mm balloon-expandable valve (Edwards Lifesciences) within the self-expanding valve (SEV) to postdilate the SEV and minimize paravalvular leak (PVL). All 4 procedures were technically successful. The patient who received rescue valve-in-valve TAVR continued to have persistent mild to moderate PVL.

CONCLUSION

Although technically challenging, TAVR is a feasible option for carefully selected LVAD patients with severe AR. Procedural issues to consider include oversizing the transcatheter heart valve (THV) while being cognizant of the risks of annular rupture and valve dislocation, anticipating and avoiding ventricular migration of the THV and being ready to postdilate the THV if necessary, to limit hemodynamically significant PVL.

Для цитирования: Dhillon Ashwat S, Jones Brandon M, Hodson Robert W, Korngold Ethan C. Transcatheter Aortic Valve Replacement for Severe Aortic Regurgitation in Patients With a Left Ventricular Assist Device.. The Journal of invasive cardiology. 2022. DOI: 10.25270/jic/21.00212.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.