MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rvsc.2020.06.017

Медицинская библиотека · Research in veterinary science · 2020

Accuracy of differences in blood and peritoneal glucose to differentiate between septic and non-septic peritonitis in horses.

Alonso Juliana de Moura, Esper Carolina Soares, Pantoja José Carlos Figueiredo, Rosa Gustavo Dos Santos, Giampietro Rodrigo Rosa, Dos Santos Bruna, Guerra Simony Trevizan, Ribeiro Márcio Garcia, Takahira Regina Kiomi, Watanabe Marcos Jun, Alves Ana Liz Garcia, Rodrigues Celso Antônio, García Henry David Mogollón, Hussni Carlos Alberto

СтатьяПеревод пока не подготовлен

Аннотация

Difference in blood and peritoneal glucose (DBPG) is used in clinical practice to support a diagnosis of septic peritonitis in horses. It is inexpensive, easy and rapid to perform. The aim of this study was to evaluate the accuracy of the DBPG to differentiate between septic and non-septic peritonitis in horses. Blood and peritoneal fluids were harvested from suspected animals. Plasma and peritoneal glucose levels, total nucleated cell count, direct microscopic and microbiological examinations of the peritoneal fluid were evaluated. Using DBPG levels, the animals were classified into two groups: difference ≥ 50 mg/dL (positive test) and difference < 50 mg/dL (negative test). Positive microbiological examination and/or presence of bacteria in direct microscopic examination was used as a gold standard to detect septic peritonitis. The accuracy parameters analysed were: sensitivity, specificity, and positive/negative predictive values, for which the results were respectively: 0.23, 0.91, 0.60 and 0.67. Due to poor accuracy, other cut-off margins and peritoneal glucose concentrations were evaluated. The test was considered most accurate when the DBPG was zero with sensitivity, specificity, and positive/negative predictive values of 0.85, 0.82, 0.73, 0.90 respectively. Peritoneal glucose concentrations alone were not a reliable feature to detect peritonitis. DBPG ≥50 mg/dL, widely used for the diagnosis of septic peritonitis, does not have a good accuracy and the DBPG = 0 has a better accuracy for detecting the disease.

Для цитирования: Alonso Juliana de Moura, Esper Carolina Soares, Pantoja José Carlos Figueiredo, Rosa Gustavo Dos Santos, Giampietro Rodrigo Rosa, Dos Santos Bruna, Guerra Simony Trevizan, Ribeiro Márcio Garcia, Takahira Regina Kiomi, Watanabe Marcos Jun, Alves Ana Liz Garcia, Rodrigues Celso Antônio, García Henry David Mogollón, Hussni Carlos Alberto. Accuracy of differences in blood and peritoneal glucose to differentiate between septic and non-septic peritonitis in horses.. Research in veterinary science. 2020. DOI: 10.1016/j.rvsc.2020.06.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.