BACKGROUND

The purpose of the present study was to investigate regional fundus pulsations in age-related macular degeneration (AMD) patients with subretinal neovascular membranes.

METHODS

Local fundus pulsation amplitudes (FPAs) were measured in 12 patients with AMD with classic neovascular membranes. Measurements were performed directly on the membrane and adjacent to the membrane. FPAs were assessed with a recently developed laser interferometric method. FPA measurements were performed in 12 healthy subjects at similar posterior pole locations.

RESULTS

In AMD patients FPAs were consistently lower when measured directly on the neovascular membrane ("inside") than at measurement sites around the membrane ("outside"). The difference in FPA was 26 +/- 3% (mean +/- SEM, range 13-40%, P < 0.0001). In healthy subjects, however, FPAs were significantly higher at the measurement points corresponding to "inside" points (15 +/- 4%, P < 0.0006).

CONCLUSIONS

We have shown that FPAs are reduced at classic neovascular membranes in patients with AMD. The mechanism behind this finding remains unclear. Hence, future studies have to ascertain whether this observation is associated with changes in fundus layers or with local choroidal perfusion abnormalities.

Для цитирования: Schmetterer L, Kruger A, Findl O, Breiteneder H, Eichler H G, Wolzt M. Topical fundus pulsation measurements in age-related macular degeneration.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 1998. DOI: 10.1007/s004170050058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.