MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2025.05.003

Медицинская библиотека · JACC. Cardiovascular interventions · 2025

Prosthesis-Patient Mismatch in Young and Low-Risk Patients After Newer Generation Balloon-Expandable Transcatheter Aortic Valve Replacement.

Suruga Kazuki, Patel Vivek, Nagasaka Takashi, Guo Yuchao, Madaan Prateek, Koren Ofir, Patel Dhairya, Harutyunyan Izabela, Gupta Aakriti, Chakravarty Tarun, Cheng Wen, Jilaihawi Hasan, Nakamura Mamoo, Makkar Raj R

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) is not well known in young and low-risk patients.

OBJECTIVES

The aim of this single-center study was to evaluate the incidence, predictors, and long-term impact of PPM in young and low-risk patients with severe native aortic stenosis (AS) following TAVR.

METHODS

From August 2015 to December 2022, a total of 3,549 patients underwent TAVR with newer generation balloon-expandable valves. Among them, 512 patients with severe native AS who were younger than 75 years and had Society of Thoracic Surgeons scores <4% were included. All-cause and cardiovascular mortality or heart failure hospitalization during follow-up period were compared between the PPM and non-PPM groups. PPM was defined according to the Valve Academic Research Consortium-3 criteria.

RESULTS

PPM was observed in 200 of 512 patients (39.0%), with moderate and severe PPM in 162 of 512 (31.6%) and 38 of 512 (7.4%), respectively. Younger age, female sex, larger body surface area, no balloon postdilation, and smaller annular area were independent predictors of PPM. Over a median follow-up duration of 1,034 days (Q1-Q3: 550-1,567 days), compared with the non-PPM group, the PPM group had significantly higher all-cause mortality (HR: 2.55; 95% CI: 1.3-5.0; P = 0.007), cardiovascular mortality (HR: 2.81; 95% CI: 1.1-7.5; P = 0.04), and heart failure hospitalization (HR: 4.43; 95% CI: 2.0-9.9; P < 0.001).

CONCLUSIONS

PPM is associated with worse clinical outcomes in young and low-risk patients with AS after TAVR, even with newer generation balloon-expandable valves.

Для цитирования: Suruga Kazuki, Patel Vivek, Nagasaka Takashi, Guo Yuchao, Madaan Prateek, Koren Ofir, Patel Dhairya, Harutyunyan Izabela, Gupta Aakriti, Chakravarty Tarun, Cheng Wen, Jilaihawi Hasan, Nakamura Mamoo, Makkar Raj R. Prosthesis-Patient Mismatch in Young and Low-Risk Patients After Newer Generation Balloon-Expandable Transcatheter Aortic Valve Replacement.. JACC. Cardiovascular interventions. 2025. DOI: 10.1016/j.jcin.2025.05.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.