MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2025.03.015

Медицинская библиотека · The Annals of thoracic surgery · 2025

Five-Year Results of Aortic Valve Replacement With a Novel Bioprosthesis: Real-World Data From a Large Multicenter Registry.

Onorati Francesco, Geisler Daniela, Theron Alexis, Francica Alessandra, Caruso Vincenzo, Mariani Carlo, Fiore Antonio, Hegeman Romy, Porto Alizee, Folliguet Thierry, Lucchese Gianluca, Klein Patrick, Pacini Davide, Grabenwöger Martin, Luciani Giovanni Battista

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The clinical performance and safety of a glutaraldehyde-free bioprosthetic valve using a novel tissue treatment in a large real-world patient population have not previously been reported.

METHODS

This is a prospective, multicenter, real-world registry of all patients undergoing surgical aortic valve replacement with a novel bioprosthesis at 7 European cardiac surgery centers. The primary end point was the 5-year freedom from structural valve deterioration per Valve Academic Research Consortium 3 criteria. Secondary end points included hemodynamic performance of the bioprosthesis and freedom from all-cause and cardiovascular mortality, prosthetic endocarditis, stroke, and reintervention at 5 years.

RESULTS

A total of 498 patients were included in the analysis; the mean age was 60.1 years, with a mean EuroSCORE II of 3.9% and 27.9% being female. The median follow-up was 4.8 years. Five-year freedom from structural valve deterioration stages 1, 2, and 3 was 95.7%, 98.6%, and 99.3%, respectively. The estimated 5-year overall survival was 93.2%; freedom from cardiovascular mortality was 97.2%. Event-free probabilities at 5 years for endocarditis, stroke, and reintervention were 98.6%, 98.1%, and 98.2%, respectively. Moderate-severe paravalvular leakage was infrequent (97.3% event-free probability at 5 years), and mean aortic valve pressure gradient was stable compared with discharge (median, 11.0 mm Hg at discharge vs 12.0 mm Hg at 5 years).

CONCLUSIONS

These real-world clinical data of a novel aortic bioprosthesis demonstrated good 5-year results for both durability and safety outcomes as well as stable hemodynamic valve performance.

Для цитирования: Onorati Francesco, Geisler Daniela, Theron Alexis, Francica Alessandra, Caruso Vincenzo, Mariani Carlo, Fiore Antonio, Hegeman Romy, Porto Alizee, Folliguet Thierry, Lucchese Gianluca, Klein Patrick, Pacini Davide, Grabenwöger Martin, Luciani Giovanni Battista. Five-Year Results of Aortic Valve Replacement With a Novel Bioprosthesis: Real-World Data From a Large Multicenter Registry.. The Annals of thoracic surgery. 2025. DOI: 10.1016/j.athoracsur.2025.03.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.