Artificial intelligence-enhanced comprehensive assessment of the aortic valve stenosis continuum in echocardiography.

Park Jiesuck, Kim Jiyeon, Jeon Jaeik, Yoon Yeonyee E, Jang Yeonggul, Jeong Hyunseok, Hong Youngtaek, Lee Seung-Ah, Choi Hong-Mi, Hwang In-Chang, Cho Goo-Yeong, Chang Hyuk-Jae

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Transthoracic echocardiography (TTE) is the primary modality for diagnosing aortic stenosis (AS), yet it requires skilled operators and can be resource-intensive. We developed and validated an artificial intelligence (AI)-based system for evaluating AS that is effective in both resource-limited and advanced settings.

METHODS

We created a dual-pathway AI system for AS evaluation using a nationwide echocardiographic dataset (developmental dataset, n = 8427): 1) a deep learning (DL)-based AS continuum assessment algorithm using limited 2D TTE videos, and 2) automating conventional AS evaluation. We performed internal (internal test dataset [ITDS], n = 841) and external validation (distinct hospital dataset [DHDS], n = 1696; temporally distinct dataset [TDDS], n = 772) for diagnostic value across various stages of AS and prognostic value for composite endpoints (cardiovascular death, heart failure, and aortic valve replacement).

FINDINGS: The DL index for the AS continuum (DLi-ASc, range 0-100) increased with worsening AS severity and demonstrated excellent discrimination for any AS (AUC 0.91-0.99), significant AS (0.95-0.98), and severe AS (0.97-0.99). DLi-ASc was independent predictor for composite endpoint (adjusted hazard ratios 2.19, 1.64, and 1.61 per 10-point increase in ITDS, DHDS, and TDDS, respectively). Automatic measurement of conventional AS parameters demonstrated excellent correlation with manual measurement, resulting in high accuracy for AS staging (98.2% for ITDS, 82.1% for DHDS, and 96.8% for TDDS) and comparable prognostic value to manually-derived parameters.

INTERPRETATION: The AI-based system provides accurate and prognostically valuable AS assessment, suitable for various clinical settings. Further validation studies are planned to confirm its effectiveness across diverse environments.

FUNDING: This work was supported by a grant from the Institute of Information & Communications Technology Planning & Evaluation (IITP) funded by the Korea government (Ministry of Science and ICT; MSIT, Republic of Korea) (No. 2022000972, Development of a Flexible Mobile Healthcare Software Platform Using 5G MEC); and the Medical AI Clinic Program through the National IT Industry Promotion Agency (NIPA) funded by the MSIT, Republic of Korea (Grant No.: H0904-24-1002).

Для цитирования: Park Jiesuck, Kim Jiyeon, Jeon Jaeik, Yoon Yeonyee E, Jang Yeonggul, Jeong Hyunseok, Hong Youngtaek, Lee Seung-Ah, Choi Hong-Mi, Hwang In-Chang, Cho Goo-Yeong, Chang Hyuk-Jae. Artificial intelligence-enhanced comprehensive assessment of the aortic valve stenosis continuum in echocardiography.. EBioMedicine. 2025. DOI: 10.1016/j.ebiom.2025.105560.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.