MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jvh.13672

Медицинская библиотека · Journal of viral hepatitis · 2022

Determining the lower limit of detection required for HCV viral load assay for test of cure following direct-acting antiviral-based treatment regimens: Evidence from a global data set.

Morgan Jake R, Marsh Elizabeth, Savinkina Alexandra, Shilton Sonjelle, Shadaker Shaun, Tsertsvadze Tengiz, Kamkamidze George, Alkhazashvili Maia, Morgan Timothy, Belperio Pam, Backus Lisa, Doss Waheed, Esmat Gamal, Hassany Mohamed, Elsharkawy Aisha, Elakel Wafaa, Mehrez Mai, Foster Graham R, Wose Kinge Constance, Chew Kara W, Chasela Charles S, Sanne Ian M, Thanung Yin M, Loarec Anne, Aslam Khawar, Balkan Suna, Easterbrook Philippa J, Linas Benjamin P

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Achieving global elimination of hepatitis C virus requires a substantial scale-up of testing. Point-of-care HCV viral load assays are available as an alternative to laboratory-based assays to promote access in hard to reach or marginalized populations. The diagnostic performance and lower limit of detection are important attributes of these new assays for both diagnosis and test of cure. Therefore, our objective was to determine an acceptable LLoD for detectable HCV viraemia as a test for cure, 12 weeks post-treatment (SVR12). We assembled a global data set of patients with detectable viraemia at SVR12 from observational databases from 9 countries (Egypt, the United States, United Kingdom, Georgia, Ukraine, Myanmar, Cambodia, Pakistan, Mozambique) and two pharmaceutical-sponsored clinical trial registries. We examined the distribution of HCV viral load at SVR12 and presented the 90th, 95th, 97th and 99th percentiles. We used logistic regression to assess characteristics associated with low-level virological treatment failure (defined as <1000 IU/mL). There were 5973 cases of detectable viraemia at SVR12 from the combined data set. Median detectable HCV RNA at SVR12 was 287,986 IU/mL. The level of detection for the 95th percentile was 227 IU/mL (95% CI 170-276). Females and those with minimal fibrosis were more likely to experience low-level viraemia at SVR12 compared to men (adjusted odds ratio AOR = 1.60 95% confidence interval [CI] 1.30-1.97 and those with cirrhosis (AOR = 1.49 95% CI 1.15-1.93). In conclusion, an assay with a level of detection of 1000 IU/mL or greater may miss a proportion of those with low-level treatment failure.

Для цитирования: Morgan Jake R, Marsh Elizabeth, Savinkina Alexandra, Shilton Sonjelle, Shadaker Shaun, Tsertsvadze Tengiz, Kamkamidze George, Alkhazashvili Maia, Morgan Timothy, Belperio Pam, Backus Lisa, Doss Waheed, Esmat Gamal, Hassany Mohamed, Elsharkawy Aisha, Elakel Wafaa, Mehrez Mai, Foster Graham R, Wose Kinge Constance, Chew Kara W, Chasela Charles S, Sanne Ian M, Thanung Yin M, Loarec Anne, Aslam Khawar, Balkan Suna, Easterbrook Philippa J, Linas Benjamin P. Determining the lower limit of detection required for HCV viral load assay for test of cure following direct-acting antiviral-based treatment regimens: Evidence from a global data set.. Journal of viral hepatitis. 2022. DOI: 10.1111/jvh.13672.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.