A quick and simple benchtop vortex egg-disruption approach for the molecular diagnosis of Fasciola hepatica from ruminant faecal samples.

Calvani Nichola Eliza Davies, Cheng Tina, Green Christine, Hughes Patrick, Kwan Emily, Maher Elizabeth, Bush Russell David, Šlapeta Jan

СтатьяПеревод пока не подготовлен

Аннотация

Commonly employed diagnostic methods for Fasciola spp., such as a traditional sedimentation and faecal egg count, or a commercially available coprological ELISA, have limitations in their sensitivity or ability to differentiate species. A reliable DNA isolation method coupled with real-time PCR addresses these issues by providing highly sensitive and quantitative molecular diagnosis from faecal samples. The current study evaluated a standard benchtop vortex for F. hepatica egg disruption in sheep and cattle faecal samples and determined the minimum faecal egg load required for a positive result from un-concentrated (raw) faecal samples. The minimum faecal egg load for a positive real-time PCR result from 150 mg raw faecal sample was 10 and 20 eggs per gram for sheep and cattle, respectively. No significant difference (P = 0.4467) between disruptions on a benchtop vortex for 5 or 10 min was observed when compared to 40 s of disruption at 6.0 m/s in a benchtop homogeniser.

Для цитирования: Calvani Nichola Eliza Davies, Cheng Tina, Green Christine, Hughes Patrick, Kwan Emily, Maher Elizabeth, Bush Russell David, Šlapeta Jan. A quick and simple benchtop vortex egg-disruption approach for the molecular diagnosis of Fasciola hepatica from ruminant faecal samples.. Parasitology research. 2018. DOI: 10.1007/s00436-018-5926-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.