MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0044-1780523

Медицинская библиотека · American journal of perinatology · 2024

Variability in Practice and Implementation of Oxygen Target Saturation Policies in United States' Neonatal Intensive Care Units.

Parikh Pratik, White Robert D, Tolia Veeral N, Reyburn Brent, Guillory Charleta, Ahmad Kaashif A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aimed to describe target oxygen saturation (SpO2) ranges used for premature infants in United States' neonatal intensive care units (NICUs) and to describe if these target SpO2 ranges have changed in recent years.

STUDY

DESIGN

A 29-question survey focused on target SpO2 practices and policies was distributed via the NICU medical directors listservs for the American Academy of Pediatrics Section of Neonatal-Perinatal Medicine and Pediatrix Medical Group between August and October of 2021. Results were collected via Research Electronic Data Capture (REDCap).

RESULTS

We received responses representing 170 unique, levels 2, 3, and 4 NICUs from 36 states. Most NICUs (130, 78%) have recently changed their SpO2 targets in response to target SpO2 clinical trials. Over time, the most commonly reported target SpO2 range has shifted from 88-92% to 90-95. Of NICUs that changed limits, the most common lower SpO2 limits increased from 88 to 90% and the upper SpO2 limits changed from 92 to 95%. The interquartile range for lower SpO2 limit shifted from 85-88% to 88-90% and the IQR for upper SpO2 limit decreased from 92-95 to 94-95%. Most NICUs had designated conditions that would allow for deviations from standard target SpO2 ranges. These most commonly include pulmonary hypertension (152, 95%), severe bronchopulmonary dysplasia (81, 51%), and retinopathy of prematurity (51, 32%).

CONCLUSION

Oxygen saturation limits have changed over time with an overall increase in targeted SpO2. However, there remains considerable interunit variation in SpO2 policies. There is a need to achieve consensus to optimize clinical outcomes.

KEY POINTS: · What are the SpO2 ranges in United States' NICUs?. · There is a shift in SpO2 ranges for preterm infants in NICUs across United States.. · Variability still persists in SpO2 ranges for preterm infants in United States' NICUs..

Для цитирования: Parikh Pratik, White Robert D, Tolia Veeral N, Reyburn Brent, Guillory Charleta, Ahmad Kaashif A. Variability in Practice and Implementation of Oxygen Target Saturation Policies in United States' Neonatal Intensive Care Units.. American journal of perinatology. 2024. DOI: 10.1055/s-0044-1780523.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.