m+Medelevator.RU
← Поиск публикаций
American journal of respiratory and critical care medicine · 2011

Reslizumab for poorly controlled, eosinophilic asthma: a randomized, placebo-controlled study.

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Castro Mario, Mathur Sameer, Hargreave Frederick, Boulet Louis-Philippe, Xie Fang, Young James, Wilkins H Jeffrey, Henkel Timothy, Nair Parameswaran, Res-5-0010 Study Group

Аннотация

RATIONALE: Eosinophilic asthma is a phenotype of asthma characterized by the persistence of eosinophils in the airways. IL-5 is involved in the activation and survival of eosinophils.

OBJECTIVES: To evaluate the effect of the antibody to IL-5, reslizumab, in patients with eosinophilic asthma that is poorly controlled with high-dose inhaled corticosteroid.

METHODS: Patients were randomly assigned to receive infusions of reslizumab at 3.0 mg/kg (n = 53) or placebo (n = 53) at baseline and at Weeks 4, 8, and 12, with stratification by baseline Asthma Control Questionnaire (ACQ) score less than or equal to 2 or greater than 2. The primary efficacy measure was the difference between the reslizumab and placebo groups in the change in ACQ score from baseline to end of therapy (Week 15 or early withdrawal).

MEASUREMENTS AND MAIN RESULTS: Mean changes from baseline to end of therapy in ACQ score were -0.7 in the reslizumab group and -0.3 in the placebo group (P = 0.054) and in FEV(1) were 0.18 and -0.08 L, respectively (P = 0.002). In those patients with nasal polyps, the changes in ACQ score were -1.0 and -0.1, respectively (P = 0.012). Median percentage reductions from baseline in sputum eosinophils were 95.4 and 38.7%, respectively (P = 0.007). Eight percent of patients in the reslizumab group and 19% of patients in the placebo group had an asthma exacerbation (P = 0.083). The most common adverse events with reslizumab were nasopharyngitis, fatigue, and pharyngolaryngeal pain.

CONCLUSIONS: Patients receiving reslizumab showed significantly greater reductions in sputum eosinophils, improvements in airway function, and a trend toward greater asthma control than those receiving placebo. Reslizumab was generally well tolerated.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты