DOI 10.1186/s12909-025-07381-7
Construction of a simulation scenario and a low-cost simulator for teaching thoracentesis procedural technique: a validation study.
Аннотация
BACKGROUND
Thoracentesis yields valuable insights in pleural effusion diagnosis by accurately interpreting pleural fluid analysis results and can cause several complications, which emphasizes the importance of training in a simulated environment. There are many expensive simulators related to this procedure and few validated scenarios. This study aimed to build and validate a low-cost simulator and a clinical simulation scenario for teaching the thoracentesis procedural technique to undergraduate medical students.
METHODS
This is a methodological study carried out at a public university in the interior of the state of São Paulo, Brazil. It was carried out in three methodological stages, namely: 1) Construction of the simulator, which involved planning, surveying, pricing, and use of material resources 2) Construction of a simulated thoracentesis scenario, based on literature and a simulation script and 3) Validation by experts and pilot study of the simulator and scenario. Experts were selected according to Fehring criteria.
RESULTS
The simulator proved to be suitable and low-cost (US $18). Modifications to the scenario were suggested by the experts and students in the pilot study, with 100.0% agreement.
CONCLUSIONS
In conclusion, a low-tech, handmade, and low-cost simulator was built and evaluated for training in the thoracentesis procedural technique, as well as a clinical simulation scenario for the management of patients with pleural effusion, which can be included in various medical teaching contexts.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.