m+Medelevator.RU
← Поиск публикаций
BMJ open · 2023

Evaluation of the prehospital use of a Valsalva assist device in the emergency treatment of supraventricular tachycardia (EVADE SVT): study protocol for a stepped wedge cluster randomised controlled trial.

Протокол клинического исследованияСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Appelboam Andrew, Osborne Ria, Ukoumunne Obioha, Black Sarah, Boot Suzanne, Richards Nicholas, Scotney Natalie, Rhodes Shelley, Cranston Tim, Hawker Ruth, Gillett Annette, Jones Ben, Hawton Annie, Dayer Mark, Creanor Siobhan, EVADE SVT Study Collaborators

Аннотация

INTRODUCTION: Patients with episodes of supraventricular tachycardia (SVT), a common heart arrhythmia, are often attended by ambulance services. International guidelines advocate treatment with the Valsalva manoeuvre (VM), but this simple physical treatment has a low success rate, with most patients requiring conveyance to hospital. The Valsalva Assist Device (VAD) is a simple device that might help practitioners and patients perform a more effective VM and reduce the need for patients to be taken to hospital.

METHODS AND ANALYSIS: This stepped wedge cluster randomised controlled trial, conducted within a UK ambulance service, compares the current standard VM with a VAD-delivered VM in stable adult patients presenting to the ambulance service with SVT. The primary outcome is conveyance to hospital; secondary outcomes measures include cardioversion rates, duration of ambulance care and number of subsequent episodes of SVT requiring ambulance service care. We plan to recruit approximately 800 patients, to have 90% power to detect an absolute reduction in conveyance rate of 10% (from 90% to 80%) between the standard VM (control) and VAD-delivered VM (intervention). Such a reduction in conveyance would benefit patients, the ambulance service and receiving emergency departments. It is estimated potential savings would pay for devices for the entire ambulance trust within 7 months.

ETHICS AND DISSEMINATION: The study has been approved by the Oxford Research Ethics Committee (reference 22/SC/0032). Dissemination will be through peer-reviewed journal publication, presentation at national and international conferences and by the Arrhythmia Alliance, a patient support charity.

TRIAL REGISTRATION NUMBER: ISRCTN16145266.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты