Concordant and discordant breast density patterns by different approaches for assessing breast density and breast cancer risk.

Cho Yoosun, Park Eun Kyung, Chang Yoosoo, Kwon Mi-Ri, Kim Eun Young, Kim Minjeong, Park Boyoung, Lee Sanghyup, Jeong Han Eol, Kim Ki Hwan, Kim Tae Soo, Lee Hyeonsoo, Kwon Ria, Lim Ga-Young, Choi JunHyeok, Kook Shin Ho, Ryu Seungho

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To examine the discrepancy in breast density assessments by radiologists, LIBRA software, and AI algorithm and their association with breast cancer risk.

METHODS

Among 74,610 Korean women aged ≥ 34 years, who underwent screening mammography, density estimates obtained from both LIBRA and the AI algorithm were compared to radiologists using BI-RADS density categories (A-D, designating C and D as dense breasts). The breast cancer risks were compared according to concordant or discordant dense breasts identified by radiologists, LIBRA, and AI. Cox-proportional hazards models were used to determine adjusted hazard ratios (aHRs) [95% confidence intervals (CIs)].

RESULTS

During a median follow-up of 9.9 years, 479 breast cancer cases developed. Compared to the reference non-dense breast group, the aHRs (95% CIs) for breast cancer were 2.37 (1.68-3.36) for radiologist-classified dense breasts, 1.30 (1.05-1.62) for LIBRA, and 2.55 (1.84-3.56) for AI. For different combinations of breast density assessment, aHRs (95% CI) for breast cancer were 2.40 (1.69-3.41) for radiologist-dense/LIBRA-non-dense, 11.99 (1.64-87.62) for radiologist-non-dense/LIBRA-dense, and 2.99 (1.99-4.50) for both dense breasts, compared to concordant non-dense breasts. Similar trends were observed with radiologists/AI classification: the aHRs (95% CI) were 1.79 (1.02-3.12) for radiologist-dense/AI-non-dense, 2.43 (1.24-4.78) for radiologist-non-dense/AI-dense, and 3.23 (2.15-4.86) for both dense breasts.

CONCLUSION

The risk of breast cancer was highest in concordant dense breasts. Discordant dense breast cases also had a significantly higher risk of breast cancer, especially when identified as dense by either AI or LIBRA, but not radiologists, compared to concordant non-dense breast cases.

Для цитирования: Cho Yoosun, Park Eun Kyung, Chang Yoosoo, Kwon Mi-Ri, Kim Eun Young, Kim Minjeong, Park Boyoung, Lee Sanghyup, Jeong Han Eol, Kim Ki Hwan, Kim Tae Soo, Lee Hyeonsoo, Kwon Ria, Lim Ga-Young, Choi JunHyeok, Kook Shin Ho, Ryu Seungho. Concordant and discordant breast density patterns by different approaches for assessing breast density and breast cancer risk.. Breast cancer research and treatment. 2024. DOI: 10.1007/s10549-024-07541-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.