Understanding the risk of ionizing radiation in breast imaging: Concepts and quantities, clinical importance, and future directions.

Di Maria S, van Nijnatten T J A, Jeukens C R L P N, Vedantham S, Dietzel M, Vaz P

СтатьяОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Conventional mammography remains the primary imaging modality for state-of-the-art breast imaging practice and its benefit (both on diagnostic and screening) was largely reported. In mammography, the typical Mean Glandular Dose (MGD) from X-ray radiation to the breast spans, on average, from 1 to 10 mGy, depending on breast thicknesses, percentage of fibroglandular tissue, and on the examination purpose.

METHODS

The aim of this narrative review is to describe the extent of radiation risk in X-ray breast imaging and discuss the main steps and parameters (e.g. MGD, screening frequency and number of examination views) that may have an influence on the radiation risk assessment.

RESULTS

Even though the radiation doses used with these examinations are very low, as compared to other medical or natural radiation exposures, there is a non-negligible associated risk of radiation-induced cancer. Accurate radiation risk assessment permits to better balance the overall estimation of the benefit-to-risk ratio in X-ray breast imaging.

CONCLUSIONS

It is expected that a better knowledge about radiation-induced cancer risk among population could improve the communications skills between patients and clinicians and could help to increase the awareness in women about radiation risk perception for a transparent and proper informed choice of imaging exam.

Для цитирования: Di Maria S, van Nijnatten T J A, Jeukens C R L P N, Vedantham S, Dietzel M, Vaz P. Understanding the risk of ionizing radiation in breast imaging: Concepts and quantities, clinical importance, and future directions.. European journal of radiology. 2024. DOI: 10.1016/j.ejrad.2024.111784.