BACKGROUND

Early recurrence of atrial tachyarrhythmia (ERAT) is associated with ablation-induced proarrhythmogenic inflammation; however, existing studies used intermittent monitoring or nonoptimized radiofrequency (RF) applications (noncontiguous or without ablation index target value).

OBJECTIVE

The purpose of this study was to investigate the relationship between ERAT and late recurrence based on insertable cardiac monitor (ICM) data.

METHODS

We compiled data from Close-To-Cure and Close Maze studies, which enrolled patients who underwent RF ablation for paroxysmal or persistent atrial fibrillation (AF). All patients were implanted with an ICM 2-3 months before ablation.

RESULTS

We studied 165 patients (104 with paroxysmal AF, 61 with persistent AF). Over the 1-year follow-up period, 41 of the patients experienced late recurrence. The risk of late recurrence was higher in patients experiencing ERAT (hazard ratio [HR] 6.2; 95% confidence interval [CI] 3.0-13.0), with negative and positive predictive values of 90.5% and 45.7%, respectively. Median burden of AF during the blanking period was significantly higher in patients with late recurrence (7.9% [0.0%-99.6%]) compared to those without recurrence (0.0% [0.0%-6.0]; P <.001). For each 1% increase in AF burden during the blanking period, late recurrence increased by 4.6% (HR 1.046; 95% CI 1.035-1.059). The best tradeoff for predicting AF from ERAT occurrence was AF burden of 0.6% and last ERAT at 64 days.

CONCLUSION

In patients ablated for paroxysmal and persistent AF with a durable RF lesion set and implanted with a continuous monitoring device, postablation early AF recurrence and burden significantly predict late recurrence. The post-AF ablation blanking period should be reduced to 2 months.

Для цитирования: De Becker Benjamin, El Haddad Milad, De Smet Maarten, François Clara, Tavernier René, le Polain de Waroux Jean-Benoit, Duytschaever Mattias, Knecht Sébastien. Early atrial fibrillation recurrence post catheter ablation: Analysis from insertable cardiac monitor in the era of optimized radiofrequency ablation.. Heart rhythm. 2024. DOI: 10.1016/j.hrthm.2024.01.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.