Takagi Takamitsu, Derval Nicolas, Duchateau Josselin, Chauvel Rémi, Tixier Romain, Marchand Hugo, Bouyer Benjamin, André Clémentine, Kamakura Tsukasa, Krisai Philipp, Ascione Ciro, Balbo Conrado, Cheniti Ghassen, Denis Arnaud, Sacher Frédéric, Hocini Mélèze, Jaïs Pierre, Haïssaguerre Michel, Pambrun Thomas

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Beyond pulmonary vein (PV) isolation, anatomic isthmus transection is an adjunctive strategy for persistent atrial fibrillation. Data on the durability of multiple lines of block remain scarce.

OBJECTIVE

The purpose of this study was to evaluate the impact of gaps within such a lesion set.

METHODS

We followed 291 consecutive patients who underwent (1) vein of Marshall ethanol infusion, (2) PV isolation, and (3) mitral, cavotricuspid, and dome isthmus transection. Dome transection relied on 2 distinct strategies over time: a single roof line with touch-ups applied in case of gap demonstrated by conventional maneuvers (first leg), and an alternative floor line if the roof line exhibited a gap during high-density mapping with careful electrogram reannotation (second leg).

RESULTS

Twelve-month sinus rhythm maintenance was 70% after 1 procedure and 94% after 1 or 2 procedures. Event-free survival after the first procedure was lower in case of residual gaps within the lesion set (log-rank, P = .004). Delayed gaps were found in 94% of a second procedure performed in the 69 patients relapsing despite a complete lesion set with PV gaps increasing the risk of recurrence of atrial fibrillation (67% vs 34%; P = .02) and anatomic isthmus gaps supporting a majority of atrial tachycardias (60%). Between the first leg and the second leg, a significant decrease was found in roof lines considered blocked during the first procedure (99% vs 78%; P < .001) and in delayed dome gaps observed during a second procedure (68% vs 43%; P = .05).

CONCLUSION

Gaps are arrhythmogenic and can be reduced by optimized ablation and assessment of lines of block. Closing these gaps improves sinus rhythm maintenance.

Для цитирования: Takagi Takamitsu, Derval Nicolas, Duchateau Josselin, Chauvel Rémi, Tixier Romain, Marchand Hugo, Bouyer Benjamin, André Clémentine, Kamakura Tsukasa, Krisai Philipp, Ascione Ciro, Balbo Conrado, Cheniti Ghassen, Denis Arnaud, Sacher Frédéric, Hocini Mélèze, Jaïs Pierre, Haïssaguerre Michel, Pambrun Thomas. Gaps after linear ablation of persistent atrial fibrillation (Marshall-PLAN): Clinical implication.. Heart rhythm. 2022. DOI: 10.1016/j.hrthm.2022.09.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.