MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-020-00980-y

Медицинская библиотека · Japanese journal of radiology · 2020

Comparison of CT-based and MRI-based high-risk clinical target volumes in image guided-brachytherapy for cervical cancer, referencing recommendations from the Japanese Radiation Oncology Study Group (JROSG) and consensus statement guidelines from the Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC ESTRO).

Iwai Yuma, Nemoto Miho Watanabe, Horikoshi Takuro, Kanazawa Aki, Kurokawa Marie, Saito Makoto, Harada Rintaro, Kobayashi Hiroki, Uno Takashi

Сравнительное исследованиеСтатьяКлинические рекомендацииПеревод пока не подготовлен

Аннотация

PURPOSE: The Working Group of the Gynecological Tumor Committee of the Japanese Radiation Oncology Study Group (JROSG) published recommendations for contouring high-risk clinical target volumes (HR-CTV) on CT for 3-dimentional image-guided brachytherapy for cervical cancer. The purpose of this study was to compare HR-CTV delineated on CT, referencing recommendations from JROSG, with HR-CTV delineated on MRI, referencing consensus guidelines from the Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC ESTRO).

MATERIAL AND

METHODS

Fourteen patients were evaluated. After the insertion of the CT/MR applicator into the patient, CT and MRI were performed. HR-CTVMR was delineated on MRI for clinical examination and HR-CTVCT was delineated on CT retrospectively referencing the MRI just before brachytherapy within a week. The volume and dosimetry of HR-CTV based on a 6 Gy dose of the Manchester system were evaluated.

RESULTS

The median volumes of HR-CTVMR and HR-CTVCT were 24.4 ml (range, 13.6-50.4 ml) and 29.9 ml (range, 13.2-49.2 ml), respectively. Median D90 of HR-CTVMR and HR-CTVCT were 6.7 Gy (range, 5.8-10.1 Gy) and 6.8 Gy (range, 5.1-10.4 Gy), respectively.

CONCLUSION

Somewhat difference could be seen between HR-CTVMR and HR-CTVCT.

Для цитирования: Iwai Yuma, Nemoto Miho Watanabe, Horikoshi Takuro, Kanazawa Aki, Kurokawa Marie, Saito Makoto, Harada Rintaro, Kobayashi Hiroki, Uno Takashi. Comparison of CT-based and MRI-based high-risk clinical target volumes in image guided-brachytherapy for cervical cancer, referencing recommendations from the Japanese Radiation Oncology Study Group (JROSG) and consensus statement guidelines from the Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC ESTRO).. Japanese journal of radiology. 2020. DOI: 10.1007/s11604-020-00980-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.