Comparative Assessment of Reliability and Accuracy of Cone-Beam Computed Tomography (CBCT) Over Direct Surgical Measurement for Periodontal Bone Loss: A Prospective, Cross-Sectional Study.
Аннотация
INTRODUCTION
Assessing bone condition holds significant value in the diagnosis, treatment planning, and prognosing the periodontal disease; its importance is undeniable. The main aim of the present study was to evaluate the accuracy of alveolar bone measurements due to periodontal disease using cone-beam computed tomography (CBCT), by comparing with surgical measurements, considered as the gold standard.
MATERIALS AND
METHODS
A prospective cross-sectional study included a sample of 40 individuals diagnosed with chronic periodontitis who required periodontal surgery. A total of 202 sites were assessed for vertical and horizontal bone loss in the anterior (76 sites) and posterior (126 sites) teeth. Bone loss was measured using CBCT and a UNC 15 periodontal probe during the surgical intervention, and then compared. The statistical analysis involved employing a Student's t-test to compare measurements. Unpaired t-tests and correlation analyses were conducted using Pearson's correlation coefficient test. To establish statistical significance, a threshold of p<0.05 was considered appropriate.
RESULTS
The statistical analysis carried out on the mean values of CBCT and direct surgical measurements for vertical bone loss demonstrated a significant difference (p<0.01). However, the values obtained for horizontal bone loss did not display statistical significance. A strong correlation of 0.94-0.99 existed between surgical and CBCT measurements. A statistically significant distinction was observed between the two methods in measuring bone loss at the distal and palatal sites of the anterior teeth.
CONCLUSION
Both CBCT and direct surgical measurement exhibit comparable accuracy potential in assessing alveolar bone loss. CBCT provides an accessibility advantage by enhancing visual access to challenging sites during surgical interventions, including palatal and distal areas of the teeth.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.