m+Medelevator.RU
← Поиск публикаций
Nuclear medicine communications · 2022

Observer experience and accuracy of 18F-sodium-fluoride PET/CT for the diagnosis of bone metastases in prostate cancer.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zacho Helle D, Ravn Søren, Ejlersen June A, Fledelius Joan, Dolliner Peter, Nygaard Sofie T, Holdgaard Paw C, Lauridsen Jeppe F, Haarmark Christian, Hendel Helle W, Petersen Lars J

Аннотация

OBJECTIVE: To evaluate the diagnostic accuracy of observers with different levels of experience in reading 18F-sodium fluoride (NaF) PET/CT images for the diagnosis of bone metastases in prostate cancer (PCa) patients.

METHODS: Nine observers with varying NaF PET/CT experience, ranging from no experience to 2000+ examinations, evaluated 211 NaF PET/CT scans from PCa patients participating in one of four prospective trials. Each observer evaluated each NaF PET/CT on a patient level using a trichotomous scale: M0 (no bone metastases), Me (equivocal for bone metastases) and M1 (bone metastases). Subsequently, a dichotomous evaluation was conducted (M0/M1). The final diagnosis was retrieved from the original study. For each observer, ROC curves and the diagnostic accuracy were calculated based on dichotomous and trichotomous scales; in the latter case, Me was first regarded as M1 and then M0.

RESULTS: Across all experience levels, the sensitivity, specificity and accuracy using the dichotomous scale ranged from 0.81 to 0.89, 0.93 to 1.00 and 0.91 to 0.94, respectively. Employing the trichotomous scale, novice and experienced observers chose Me in up to 20 vs. 10% of cases, respectively. Considering Me as M0, the sensitivity, specificity and accuracy ranged from 0.78 to 0.89, 0.95 to 1.00 and 0.91 to 0.95, respectively. Considering Me as M1, the sensitivity, specificity and accuracy ranged from 0.86 to 0.92, 0.71 to 0.96 and 0.77 to 0.94, respectively.

CONCLUSION: Novice observers used the equivocal option more frequently than observers with NaF PET/CT experience. However, on the dichotomous scale, all observers exhibited high and satisfactory accuracy for the detection of bone metastases, making NaF PET/CT an effective imaging modality even in unexperienced hands.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты