MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr.20210886

Медицинская библиотека · The British journal of radiology · 2021

Comparison of different thresholds of PSA density for risk stratification of PI-RADSv2.1 categories on prostate MRI.

Girometti Rossano, Giannarini Gianluca, Panebianco Valeria, Maresca Silvio, Cereser Lorenzo, De Martino Maria, Pizzolitto Stefano, Pecoraro Martina, Ficarra Vincenzo, Zuiani Chiara, Valotto Claudio

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare the effect of different PSA density (PSAD) thresholds on the accuracy for clinically significant prostate cancer (csPCa) of the Prostate Imaging Reporting And Data System v.2.1 (PI-RADSv2.1).

METHODS

We retrospectively included 123 biopsy-naïve men who underwent multiparametric magnetic resonance imaging (mpMRI) and transperineal mpMRI-targeted and systematic prostate biopsy between April 2019 and October 2020. mpMRI, obtained on a 3.0T magnet with a PI-RADSv2.1-compliant protocol, was read by two radiologists (>1500/>500 mpMRI examinations). csPCa was defined as International Society of Urogenital Pathology grading group ≥2. Receiver operating characteristic analysis was used to calculate per-index lesion sensitivity, specificity, and area under the curve (AUC) of PI-RADSv.2.1 categories after adjusting for PSAD ≥0.10,≥0.15, and ≥0.20 ng/mL ml-1. Per-adjusted category cancer detection rate (CDR) was calculated, and decision analysis performed to compare PSAD-adjusted PI-RADSv.2.1 categories as a biopsy trigger.

RESULTS

csPCa prevalence was 43.9%. PSAD-adjustment increased the CDR of PI-RADSv2.1 category 4. Sensitivity/specificity/AUC were 92.6%/53.6%/0.82 for unadjusted PI-RADS, and 85.2%/72.4%/0.84, 62.9%/85.5%/0.83, and 92.4%/53.6%/0.82 when adjusting PI-RADS categories for a 0.10, 0.15, and 0.20 ng/ml ml-1 PSAD threshold, respectively. Triggering biopsy for PI-RADS four lesions and PSAD ≥0.10 ng/mL ml-1 was the strategy with greatest net benefit at 30 and 40% risk probability (0.307 and 0.271, respectively).

CONCLUSIONS

PI-RADSv2.1 category four with PSAD ≥0.10 ng/mL ml-1 was the biopsy-triggering cut-off with the highest net benefit in the range of expected prevalence for csPCa.

ADVANCES IN KNOWLEDGE: 0.10 ng/mL ml-1 is the PSAD threshold with higher clinical utility in stratifying the risk for prostate cancer of PI-RADSv.2.1 categories.

Для цитирования: Girometti Rossano, Giannarini Gianluca, Panebianco Valeria, Maresca Silvio, Cereser Lorenzo, De Martino Maria, Pizzolitto Stefano, Pecoraro Martina, Ficarra Vincenzo, Zuiani Chiara, Valotto Claudio. Comparison of different thresholds of PSA density for risk stratification of PI-RADSv2.1 categories on prostate MRI.. The British journal of radiology. 2021. DOI: 10.1259/bjr.20210886.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.