MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4111/icu.2020.61.1.28

Медицинская библиотека · Investigative and clinical urology · 2019

Comparison of prostate cancer detection rates of various prostate biopsy methods for patients with prostate-specific antigen levels of <10.0 ng/mL in real-world practice.

Oh Kyung Tak, Koo Kyo Chul, Chung Byung Ha, Lee Kwang Suk

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Several strategies of prostate biopsy (PBx) have been introduced to improve prostate cancer (PCa) detection rates. However, studies comparing cancer detection rates (CDRs) according to biopsy methods in real-world practice are scarce. This study aimed to investigate CDRs according to the biopsy methods for patients with prostate-specific antigen (PSA) <10.0 ng/mL.

MATERIALS AND

METHODS

From 2006 to 2015, patients who underwent PBx were initially selected. All patients were categorized according to the biopsy methods performed (magnetic resonance imaging targeted biopsy [MR-TBx], 12+2 hypoechoic lesion target biopsy, saturation biopsy [sPBx], extended biopsy, and 12-core PBx). The CDR of MR-TBx was compared to that of sPBx and other protocols. Volume per core (VPC) was defined as prostate volume divided by the number of biopsy cores. Patients previously diagnosed with PCa were excluded.

RESULTS

Of the 1,598 patients (median PSA, 5.41 ng/mL), 401 (25.1%) were diagnosed with PCa. Among the biopsy methods, MR-TBx has the highest CDR and proportion of Gleason score ≥7 (3+4). Biopsy methods, VPC, age, prostate volume, and PSA were associated with PCa detection. In the sub-analysis for initial biopsy, MR-TBx had no significant difference with sPBx, but had higher CDR than the other biopsy protocols. For repeat biopsy, VPC, rather than the biopsy method, was associated with CDR.

CONCLUSIONS

This study reaffirmed the efficacy of MR-TBx on CDR in real-world practice. In cases with barriers to performing magnetic resonance imaging, VPC might be useful for adjusting the optimal number of biopsy cores in repeat biopsy.

Для цитирования: Oh Kyung Tak, Koo Kyo Chul, Chung Byung Ha, Lee Kwang Suk. Comparison of prostate cancer detection rates of various prostate biopsy methods for patients with prostate-specific antigen levels of <10.0 ng/mL in real-world practice.. Investigative and clinical urology. 2019. DOI: 10.4111/icu.2020.61.1.28.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.