MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12890-016-0244-y

Медицинская библиотека · BMC pulmonary medicine · 2016

Radial endobronchial ultrasound with a guide sheath for diagnosis of peripheral cavitary lung lesions: a retrospective study.

Hayama Manabu, Okamoto Norio, Suzuki Hidekazu, Tamiya Motohiro, Shiroyama Takayuki, Tanaka Ayako, Nishida Takuji, Nishihara Takashi, Uehara Nobuko, Morishita Naoko, Kawahara Kunimitsu, Hirashima Tomonori

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Radial endobronchial ultrasound with a guide sheath (EBUS-GS) has improved the diagnostic outcomes of peripheral lung lesions. However, to our knowledge, reports on the use of EBUS-GS for diagnosis of cavitary lesions are unavailable. Therefore, this study aimed to assess the effectiveness and safety of EBUS-GS for diagnosis of peripheral cavitary lung lesions (PCLLs).

METHODS

This study was a single-institution retrospective review of PCLLs examined by using EBUS-GS between July 2013 and October 2015. The diagnostic results of different EBUS-GS samples, including cytologic, histopathologic, and microbiologic samples, were analysed separately.

RESULTS

Of 696 radial EBUS procedures performed during the study period, 50 were performed for examination of PCLLs. The overall diagnostic yield for EBUS-GS was 80 % (40/50). Regarding 27 malignant lesions, the diagnostic yields for cytologic and histopathologic samples were 63.0 % (17/27) and 74.1 % (20/27), respectively. Regarding 23 benign lesions, the diagnostic yields for histopathologic and microbiologic samples were 69.6 % (16/23) and 47.8 % (11/23), respectively. Uni- and multivariate analyses indicated that the EBUS probe being within the lesion was the only factor significantly associated with increased diagnostic yield (odds ratio, 7.04; P = 0.03). Although pulmonary infection occurred after the procedure in 1 patient (2.0 %), no other complications, including pneumothorax or significant haemorrhage, were reported.

CONCLUSION

EBUS-GS was found to be an effective and safe procedure for diagnosis of PCLLs.

Для цитирования: Hayama Manabu, Okamoto Norio, Suzuki Hidekazu, Tamiya Motohiro, Shiroyama Takayuki, Tanaka Ayako, Nishida Takuji, Nishihara Takashi, Uehara Nobuko, Morishita Naoko, Kawahara Kunimitsu, Hirashima Tomonori. Radial endobronchial ultrasound with a guide sheath for diagnosis of peripheral cavitary lung lesions: a retrospective study.. BMC pulmonary medicine. 2016. DOI: 10.1186/s12890-016-0244-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.