MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.12613

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2015

Systematic Implantation of Pacemaker/ICDs under Active Oral Anticoagulation Irrespective of Patient's Individual Preoperative Thromboembolic Risk.

Cano Óscar, Andrés Ana, Jiménez Rebeca, Osca Joaquín, Alonso Pau, Rodríguez Ydelise, Sancho-Tello María-José, Olagüe José, Castro José E, Salvador Antonio, Martínez-Dolz Luis

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

A wide variability in the perioperative management of oral anticoagulation (OAC) has been documented in patients receiving cardiac rhythm management devices (CRMDs). We sought to evaluate the safety and feasibility of a new perioperative strategy consisting in systematically continuing OAC in all patients irrespective of their individual thromboembolic (TE) risk.

METHODS

A total of 278 consecutive patients on chronic OAC receiving CRMDs were prospectively included. Patients were classified in high and low TE risk according to current guidelines for the perioperative management of antithrombotic therapy, but underwent implantation under active OAC (international normalized ratio 2-4) irrespective of their preoperative TE risk. Bleeding and TE complications were evaluated as well as other procedure-related complications, hospital stays, and the feasibility of outpatient implantations.

RESULTS

A total of 117 patients were considered at high TE risk and 161 at low TE risk. Overall, the incidence of pocket hematoma was 2.9% with only three patients requiring pocket revision. Low TE risk patients had a very low incidence of pocket hematoma (1.9%) without needing pocket revision. The mean hospital stay was 1.17 ± 1.8 days and 169 patients (61%) received their CRMD in an outpatient basis, including 77 patients who were implanted with an implantable cardioverter defibrillator. No TE events were detected during the 30-day postimplant observation period in any patient. No other significant complications related with the implant (pneumothorax, hemothorax, cardiac tamponade) were registered.

CONCLUSIONS

Systematic continuation of OAC in all patients undergoing implantation of CRMDs is safe and feasible, thus simplifying and standardizing the perioperative management in this setting.

Для цитирования: Cano Óscar, Andrés Ana, Jiménez Rebeca, Osca Joaquín, Alonso Pau, Rodríguez Ydelise, Sancho-Tello María-José, Olagüe José, Castro José E, Salvador Antonio, Martínez-Dolz Luis. Systematic Implantation of Pacemaker/ICDs under Active Oral Anticoagulation Irrespective of Patient's Individual Preoperative Thromboembolic Risk.. Pacing and clinical electrophysiology : PACE. 2015. DOI: 10.1111/pace.12613.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.