MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0301-4738.95868

Медицинская библиотека · Indian journal of ophthalmology · 2012

Scanning electron microscopy of the trabecular meshwork: understanding the pathogenesis of primary angle closure glaucoma.

Sihota Ramanjit, Goyal Amita, Kaur Jasbir, Gupta Viney, Nag Tapas C

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To study ultrastructural changes of the trabecular meshwork in acute and chronic primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG) eyes by scanning electron microscopy.

MATERIALS AND

METHODS

Twenty-one trabecular meshwork surgical specimens from consecutive glaucomatous eyes after a trabeculectomy and five postmortem corneoscleral specimens were fixed immediately in Karnovsky solution. The tissues were washed in 0.1 M phosphate buffer saline, post-fixed in 1% osmium tetraoxide, dehydrated in acetone series (30-100%), dried and mounted.

RESULTS

Normal trabecular tissue showed well-defined, thin, cylindrical uveal trabecular beams with many large spaces, overlying flatter corneoscleral beams and numerous smaller spaces. In acute PACG eyes, the trabecular meshwork showed grossly swollen, irregular trabecular endothelial cells with intercellular and occasional basal separation with few spaces. Numerous activated macrophages, leucocytes and amorphous debris were present. Chronic PACG eyes had a few, thickened posterior uveal trabecular beams visible. A homogenous deposit covered the anterior uveal trabeculae and spaces. Converging, fan-shaped trabecular beam configuration corresponded to gonioscopic areas of peripheral anterior synechiae. In POAG eyes, anterior uveal trabecular beams were thin and strap-like, while those posteriorly were wide, with a homogenous deposit covering and bridging intertrabecular spaces, especially posteriorly. Underlying corneoscleral trabecular layers and spaces were visualized in some areas.

CONCLUSIONS

In acute PACG a marked edema of the endothelium probably contributes for the acute and marked intraocular pressure (IOP) elevation. Chronically raised IOP in chronic PACG and POAG probably results, at least in part, from decreased aqueous outflow secondary to widening and fusion of adjacent trabecular beams, together with the homogenous deposit enmeshing trabecular beams and spaces.

Для цитирования: Sihota Ramanjit, Goyal Amita, Kaur Jasbir, Gupta Viney, Nag Tapas C. Scanning electron microscopy of the trabecular meshwork: understanding the pathogenesis of primary angle closure glaucoma.. Indian journal of ophthalmology. 2012. DOI: 10.4103/0301-4738.95868.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.