Fetal diagnosis and therapy · 2014
Prenatal tricuspid valve size as a predictor of postnatal outcome in patients with severe pulmonary stenosis or pulmonary atresia with intact ventricular septum.
СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lowenthal Alexander, Lemley Breniel, Kipps Alaina K, Brook Michael M, Moon-Grady Anita J
Аннотация
INTRODUCTION: Tricuspid valve (TV) size at birth correlates with intervention strategy in patients with severe pulmonary stenosis (SPS) or pulmonary atresia/intact ventricular septum (PA/IVS). Prenatal features that might predict postnatal TV size have not been well studied. We hypothesized that prenatal echocardiographic measurements predict the postnatal TV Z-score in fetuses with SPS and PA/IVS.
MATERIALS AND METHODS: We identified 16 neonates (gestational age 28 ± 4.8 weeks) with a fetal diagnosis of SPS or PA/IVS from 2001 to 2010. Measurements were performed offline. ROC (receiver operating characteristic) analysis was used to generate AUC (areas under the curve) for each of the variables.
RESULTS: AUC was 0.94 for tricuspid to mitral valve (TV/MV) ratio, 0.88 for TV Z-score, and 0.85 for TV inflow duration. A cut-off value of >0.63 for TV/MV yielded a sensitivity of 78%, specificity of 100% for predicting postnatal TV Z-score >-3. Neonates with TV Z-score ≥-3 and all fetuses with antegrade flow across the pulmonary valve or more than moderate tricuspid regurgitation had biventricular circulation in follow-up.
CONCLUSION: Fetal TV/MV >0.63 predicts favorable TV Z-score at birth in patients with SPS and PA/IVS. Antegrade pulmonary valve flow and more than moderate tricuspid regurgitation also conferred a favorable outcome.
MATERIALS AND METHODS: We identified 16 neonates (gestational age 28 ± 4.8 weeks) with a fetal diagnosis of SPS or PA/IVS from 2001 to 2010. Measurements were performed offline. ROC (receiver operating characteristic) analysis was used to generate AUC (areas under the curve) for each of the variables.
RESULTS: AUC was 0.94 for tricuspid to mitral valve (TV/MV) ratio, 0.88 for TV Z-score, and 0.85 for TV inflow duration. A cut-off value of >0.63 for TV/MV yielded a sensitivity of 78%, specificity of 100% for predicting postnatal TV Z-score >-3. Neonates with TV Z-score ≥-3 and all fetuses with antegrade flow across the pulmonary valve or more than moderate tricuspid regurgitation had biventricular circulation in follow-up.
CONCLUSION: Fetal TV/MV >0.63 predicts favorable TV Z-score at birth in patients with SPS and PA/IVS. Antegrade pulmonary valve flow and more than moderate tricuspid regurgitation also conferred a favorable outcome.