DOI 10.2214/ajr.184.6.01841960

Медицинская библиотека · AJR. American journal of roentgenology · 2005

Accuracy of image fusion using a fixation device for whole-body cancer imaging.

Nakamoto Yuji, Sakamoto Setsu, Okada Tomohisa, Matsumoto Keiichi, Minota Eiri, Kawashima Hidekazu, Senda Michio

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of this study was to evaluate the clinical feasibility of a simple image fusion technique with PET and CT images acquired separately using a vacuum cushion as a fixation device.

SUBJECTS AND

METHODS

Forty-four patients underwent whole-body PET using 18F-fluoro-2-deoxy-D-glucose (FDG) followed by CT with IV contrast material. The patients were carefully fixed in an individually molded cushion to provide the same positioning for both examinations. The PET and CT images were fused on a workstation by using the lower margin of the urinary bladder as a reference. The degree of misregistration was evaluated for the physiologic uptake of the liver and kidneys and for the pathologic uptake of lesions.

RESULTS

The average deviation of the center point of the liver between the two images was 6.6 +/- 8.7 (SD) mm in the craniocaudal direction, 1.9 +/- 5.1 mm in the anteroposterior direction, and 2.3 +/- 7.0 mm in the right-left direction. This value in the craniocaudal direction was 4.7 +/- 8.7 mm in the right kidney and 4.0 +/- 8.8 mm in the left kidney. Above the diaphragm, the deviations of the center point of movable and static lesions were 11.7 +/- 3.4 mm and 10.4 +/- 5.3 mm, respectively. Below the diaphragm, those of movable and static lesions were 9.7 +/- 2.5 mm and 6.9 +/- 2.9 mm, respectively.

CONCLUSION

Our preliminary data indicate that this technique is a simple and practical method for manual image fusion that may be acceptable in clinical settings.

Для цитирования: Nakamoto Yuji, Sakamoto Setsu, Okada Tomohisa, Matsumoto Keiichi, Minota Eiri, Kawashima Hidekazu, Senda Michio. Accuracy of image fusion using a fixation device for whole-body cancer imaging.. AJR. American journal of roentgenology. 2005. DOI: 10.2214/ajr.184.6.01841960.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.