MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/joco.joco_149_25

Медицинская библиотека · Journal of current ophthalmology · 2025

The Effect of Ambient Light Intensity on Transient Changes in Refraction and Ocular Biometric Components following Near Work: A Randomized Clinical Trial.

Mehravin Masood, Iribarren Rafael, Nabovati Payam, Jafarzadehpur Ebrahim, Falavarjani Khalil Ghasemi, Khabazkhoob Mehdi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the effect of ambient light on transient changes in refraction and ocular biometry after near work.

METHODS

This single-blind, randomized clinical trial included 87 participants randomly assigned to three groups based on ambient light levels: Group 1 (100-200 lux), Group 2 (300-400 lux), and Group 3 (500-700 lux). Each participant performed 1 h of computer-based text reading at 40 cm. Objective refraction and ocular biometric parameters, including axial length (AL), keratometry, anterior chamber depth (ACD), and lens thickness, were measured before and immediately after the task.

RESULTS

The mean ± standard deviation change in spherical equivalent (SE) was -0.72 ± 0.57 diopter in Group 1, -0.39 ± 0.34 diopter in Group 2, and -0.11 ± 0.33 diopter in Group 3 (P < 0.001). AL increased in all groups, with the largest change in Group 1 (45.16 ± 21.60 μm), followed by Group 2 (26.78 ± 13.19 μm) and Group 3 (17.83 ± 9.76 μm) (P < 0.001). Changes in keratometry (P = 0.08), ACD (P = 0.693), and lens thickness (P = 0.999) were not statistically different across the groups. Correlation analysis showed the highest association between SE and AL change in Group 1 (r = -0.703). The multiple generalized estimating equation model revealed a significant association between changes in SE and AL (β = -0.019), lens thickness (β = -0.001), and baseline SE (β = -0.485) in Group 1; AL (β = -0.009) and baseline SE (β = -0.735) in Group 2; and AL (β = -0.016) and baseline SE (β = -0.72) in Group 3.

CONCLUSIONS

Near visual tasks induce transient myopic shifts and biometric changes, primarily through axial elongation and increased lens power. This effect is influenced by ambient light, with myopic shift intensifying as light levels decrease.

Для цитирования: Mehravin Masood, Iribarren Rafael, Nabovati Payam, Jafarzadehpur Ebrahim, Falavarjani Khalil Ghasemi, Khabazkhoob Mehdi. The Effect of Ambient Light Intensity on Transient Changes in Refraction and Ocular Biometric Components following Near Work: A Randomized Clinical Trial.. Journal of current ophthalmology. 2025. DOI: 10.4103/joco.joco_149_25.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.