The Annals of thoracic surgery · 2001
A new procedure for chronic atrial fibrillation: bilateral appendage-preserving maze procedure.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Isobe F, Kumano H, Ishikawa T, Sasaki Y, Kinugasa S, Nagamachi K, Kato Y
Аннотация
BACKGROUND: Atrial transport and atrial natriuretic peptide secretion is severely reduced from normal after the maze III procedure. To improve these factors, we developed a bilateral appendage-preserving maze procedure (BAP-maze).
METHODS: Forty-six patients with chronic atrial fibrillation who underwent the BAP-maze procedure were compared with 40 patients who underwent the maze III procedure. The ratio of the peak velocity of the A and E waves of transmitral flow (transthoracic pulsed Doppler echocardiography), the left atrial appendage ejection fraction (transesophageal echocardiography), and the atrial natriuretic peptide secretory reserve during treadmill exercise test were measured at 6 months postoperatively.
RESULTS: Sinus rhythm was restored in 44 patients (95.7%) by the BAP-maze procedure and in 39 patients (97.5%) by the maze III procedure. The ratio of the peak velocity of the A and E waves was 0.52 +/- 0.22 in the BAP-maze group and 0.25 +/- 0.19 in the maze III group (p < 0.0001). The left atrial appendage ejection fraction was 44.7% +/- 11.5%, and the atrial natriuretic peptide secretory reserve was greater in the BAP maze group (p = 0.037).
CONCLUSIONS: The BAP-maze procedure improved atrial transport and atrial natriuretic peptide secretion as well as simplifying the maze operation, without decreasing its effectiveness against atrial fibrillation.
METHODS: Forty-six patients with chronic atrial fibrillation who underwent the BAP-maze procedure were compared with 40 patients who underwent the maze III procedure. The ratio of the peak velocity of the A and E waves of transmitral flow (transthoracic pulsed Doppler echocardiography), the left atrial appendage ejection fraction (transesophageal echocardiography), and the atrial natriuretic peptide secretory reserve during treadmill exercise test were measured at 6 months postoperatively.
RESULTS: Sinus rhythm was restored in 44 patients (95.7%) by the BAP-maze procedure and in 39 patients (97.5%) by the maze III procedure. The ratio of the peak velocity of the A and E waves was 0.52 +/- 0.22 in the BAP-maze group and 0.25 +/- 0.19 in the maze III group (p < 0.0001). The left atrial appendage ejection fraction was 44.7% +/- 11.5%, and the atrial natriuretic peptide secretory reserve was greater in the BAP maze group (p = 0.037).
CONCLUSIONS: The BAP-maze procedure improved atrial transport and atrial natriuretic peptide secretion as well as simplifying the maze operation, without decreasing its effectiveness against atrial fibrillation.