MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0003-4975(01)03038-7

Медицинская библиотека · The Annals of thoracic surgery · 2001

A new procedure for chronic atrial fibrillation: bilateral appendage-preserving maze procedure.

Isobe F, Kumano H, Ishikawa T, Sasaki Y, Kinugasa S, Nagamachi K, Kato Y

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Atrial transport and atrial natriuretic peptide secretion is severely reduced from normal after the maze III procedure. To improve these factors, we developed a bilateral appendage-preserving maze procedure (BAP-maze).

METHODS

Forty-six patients with chronic atrial fibrillation who underwent the BAP-maze procedure were compared with 40 patients who underwent the maze III procedure. The ratio of the peak velocity of the A and E waves of transmitral flow (transthoracic pulsed Doppler echocardiography), the left atrial appendage ejection fraction (transesophageal echocardiography), and the atrial natriuretic peptide secretory reserve during treadmill exercise test were measured at 6 months postoperatively.

RESULTS

Sinus rhythm was restored in 44 patients (95.7%) by the BAP-maze procedure and in 39 patients (97.5%) by the maze III procedure. The ratio of the peak velocity of the A and E waves was 0.52 +/- 0.22 in the BAP-maze group and 0.25 +/- 0.19 in the maze III group (p < 0.0001). The left atrial appendage ejection fraction was 44.7% +/- 11.5%, and the atrial natriuretic peptide secretory reserve was greater in the BAP maze group (p = 0.037).

CONCLUSIONS

The BAP-maze procedure improved atrial transport and atrial natriuretic peptide secretion as well as simplifying the maze operation, without decreasing its effectiveness against atrial fibrillation.

Для цитирования: Isobe F, Kumano H, Ishikawa T, Sasaki Y, Kinugasa S, Nagamachi K, Kato Y. A new procedure for chronic atrial fibrillation: bilateral appendage-preserving maze procedure.. The Annals of thoracic surgery. 2001. DOI: 10.1016/s0003-4975(01)03038-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.