The Annals of thoracic surgery · 2001
Saline-irrigated, cooled-tip radiofrequency ablation is an effective technique to perform the maze procedure.
Клиническое исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Khargi K, Deneke T, Haardt H, Lemke B, Grewe P, Müller K M, Laczkovics A
Аннотация
BACKGROUND: We evaluated the effectiveness of the saline-irrigated-cooled-tip-radiofrequency ablation (SICTRA) to produce linear intraatrial lesions.
METHODS: Thirty patients with chronic atrial fibrillation and mitral valve disease were consecutively randomized to have mitral valve operation either with a Maze procedure (group A) or without (group B). Intraatrial linear lesions were made with an SICTRA catheter (20 to 32 W; 200 to 320 mL/h saline). An echocardiography and 24-hour electrocardiogram were obtained 12 months postoperatively.
RESULTS: The cumulative frequencies of sinus rhythm in group A and B were 0.80 and 0.27 (p < 0.01). Restored biatrial contraction was present in 66.7% (6 of 9) of the group A patients in sinus rhythm. One patient from each group received a permanent pacemaker because of bradycardia. A fatal renal bleeding and mediastinitis occurred in 2 group A patients, 6 weeks postoperatively. One group A patient had sudden cardiac death at home, 4 months after operation. One patient from each group had lethal respiratory failure, 7 and 10 months after operation. Survival after 12 months for group A and B was 73% and 93% (p = 0.131).
CONCLUSIONS: The SICTRA appeared to be an effective technique to perform the Maze procedure.
METHODS: Thirty patients with chronic atrial fibrillation and mitral valve disease were consecutively randomized to have mitral valve operation either with a Maze procedure (group A) or without (group B). Intraatrial linear lesions were made with an SICTRA catheter (20 to 32 W; 200 to 320 mL/h saline). An echocardiography and 24-hour electrocardiogram were obtained 12 months postoperatively.
RESULTS: The cumulative frequencies of sinus rhythm in group A and B were 0.80 and 0.27 (p < 0.01). Restored biatrial contraction was present in 66.7% (6 of 9) of the group A patients in sinus rhythm. One patient from each group received a permanent pacemaker because of bradycardia. A fatal renal bleeding and mediastinitis occurred in 2 group A patients, 6 weeks postoperatively. One group A patient had sudden cardiac death at home, 4 months after operation. One patient from each group had lethal respiratory failure, 7 and 10 months after operation. Survival after 12 months for group A and B was 73% and 93% (p = 0.131).
CONCLUSIONS: The SICTRA appeared to be an effective technique to perform the Maze procedure.