Incidence of atrial flutter and atrial fibrillation in patients with implanted physiological pacemakers.

Ishikawa T, Sumita S, Kikuchi M, Nakagawa T, Kosuge M, Kuji N, Kimura K, Tochikubo O, Usui T, Umemura S

СтатьяПеревод пока не подготовлен

Аннотация

Atrial flutter (AF) is a troublesome arrhythmia for patients with an implanted pacemaker. Although it has recently become possible to eliminate AF by radiofrequency catheter ablation (RF-CA), the incidence of AF before and after pacemaker implantation has not been clarified. The present study was conducted with 123 consecutive patients (69.3+/-11.6 (SD) years old) implanted with pacemakers, excluding patients who had chronic atrial fibrillation (AFib) when the pacemaker was implanted; 69 patients with atrioventricular (AV) block and 54 patients with sick sinus syndrome (including 29 patients with bradycardia-tachycardia syndrome). All patients were implanted with physiological pacemakers. The follow-up period was 4.7+/-1.9 years. In 11 of the 123 patients (8.9%), AF was observed before pacemaker implantation and the incidence was significantly higher in patients with sick sinus syndrome than in those with AV block (16.7 vs 2.9%, p<0.01). Nine of the 29 patients with bradycardia-tachycardia syndrome (31%) had AF. After physiological pacemaker implantation, AF recurred in 9 of the 11 patients, and AF was newly observed in 1 patient. Thus, 10 of the 123 patients (8.1%) had AF after physiological pacemaker implantation. Recurrence of AF was not suppressed by physiological pacing. Thirty of the 123 patients had AFib before implantation of a pacemaker and its occurrence was reduced by physiological pacing (from 24.4% to 12.2%, p<0.05). The incidence of AFib in patients with AF was significantly higher than in those without AF (90.0 vs 5.3%, p<0.001). In conclusion, the recurrence of AF is not prevented by physiological pacing and is closely related to the occurrence of AFib. RF-CA should be considered in patients who have AF before pacemaker implantation.

Для цитирования: Ishikawa T, Sumita S, Kikuchi M, Nakagawa T, Kosuge M, Kuji N, Kimura K, Tochikubo O, Usui T, Umemura S. Incidence of atrial flutter and atrial fibrillation in patients with implanted physiological pacemakers.. Japanese circulation journal. 2000. DOI: 10.1253/jcj.64.505.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.