MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/tomography12010007

Медицинская библиотека · Tomography (Ann Arbor, Mich.) · 2026

Super-Resolution Deep Learning Reconstruction Improves Image Quality of Dynamic Myocardial Computed Tomography Perfusion Imaging.

Kobayashi Yusuke, Tanabe Yuki, Morikawa Tomoro, Yoshida Kazuki, Ohara Kentaro, Hosokawa Takaaki, Kouchi Takanori, Nakano Shota, Yamaguchi Osamu, Kido Teruhito

СтатьяПеревод пока не подготовлен

Аннотация

Background/

Objectives

Super-resolution deep-learning reconstruction (SR-DLR) is an advanced image reconstruction technique, but its effect on dynamic myocardial computed tomography perfusion (CTP) imaging has not been evaluated. This study aimed to examine the impact of SR-DLR on image quality and perfusion parameters in dynamic myocardial CTP.

Methods

Thirty-five patients who underwent dynamic myocardial CTP for coronary artery disease assessment were retrospectively analyzed. Two CTP datasets were reconstructed using hybrid iterative reconstruction (HIR) and SR-DLR. Image quality was compared qualitatively and quantitatively, including image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge rise slope (ERS). Equivalence of CT-derived myocardial blood flow (CT-MBF) between two reconstructions was tested using a previously reported 15% equivalence margin. Intra-patient variability of CT-MBF was evaluated using the robust coefficient of variation (rCV).

Results

In the qualitative assessment, SR-DLR had significantly higher scores in contrast (4.0 vs. 2.0) and sharpness (4.5 vs. 2.5) compared with HIR (p < 0.001), while contrast scores were similar. In the quantitative assessment, SR-DLR demonstrated significantly lower image noise (19.4 vs. 29.4 HU), and improved SNR (6.1 vs. 4.1), CNR (13.7 vs. 10.9), and ERS (171.0 vs. 135.1 HU/mm) (all p < 0.001). Mean global CT-MBF was comparable (3.15 ± 0.91 mL/g/min for HIR vs. 3.18 ± 0.97 mL/g/min for SR-DLR) and equivalence was confirmed (p = 0.022). SR-DLR significantly reduced rCV compared with HIR (36.0% vs. 41.0%, p < 0.001).

Conclusions

SR-DLR enhances image quality in dynamic myocardial CTP while maintaining mean global CT-MBF and reducing intra-patient variability.

Для цитирования: Kobayashi Yusuke, Tanabe Yuki, Morikawa Tomoro, Yoshida Kazuki, Ohara Kentaro, Hosokawa Takaaki, Kouchi Takanori, Nakano Shota, Yamaguchi Osamu, Kido Teruhito. Super-Resolution Deep Learning Reconstruction Improves Image Quality of Dynamic Myocardial Computed Tomography Perfusion Imaging.. Tomography (Ann Arbor, Mich.). 2026. DOI: 10.3390/tomography12010007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.