Cano-Martínez J A, Nicolás-Serrano G, Andrés-Grau J, Bento-Gerard J
Аннотация
OBJECTIVE: The purpose of this study is to describe the outcomes of using a triple button device for the treatment of displaced distal-third clavicle fractures (Neer, type ii-b).
MATERIAL AND METHOD: A retrospective review was conducted on a series of patients between November 2011 and December 2014. Fourteen patients initially met the inclusion criteria, but 2 were excluded, leaving 12 patients (83.3% male; mean age 32.2 years) for the final analysis at a mean follow-up of 26±11.24 months (range, 12-48). Post-operative follow-up was performed at 2 weeks (two first months), and monthly thereafter, until was achieving clinically and radiological healing. The functional outcome was evaluated using the Constant score, and DASH score in the last follow-up.
RESULTS: The mean Constant Score was 95.5±5.2 points (range, 85-100), with a mean DASH score of 3.3±4.4 points (range, 0-12.5). The mean time to clinical healing was10.3±3.1 weeks (range, 8-16), and the mean time to radiological healing was 13.6±2.6 weeks (range, 12-20). There were no major complications. There were 5 minor complications without clinical impact: 2 coracoclavicular calcifications, 1 hypertrophic scar, 1 patient with discomfort due to the device, and 1 superficial wound infection. All patients returned their previous activity.
CONCLUSION: Good clinical results can be achieved with the triple button device in unstable distal fractures of the clavicle, without the need to remove the hardware.
MATERIAL AND METHOD: A retrospective review was conducted on a series of patients between November 2011 and December 2014. Fourteen patients initially met the inclusion criteria, but 2 were excluded, leaving 12 patients (83.3% male; mean age 32.2 years) for the final analysis at a mean follow-up of 26±11.24 months (range, 12-48). Post-operative follow-up was performed at 2 weeks (two first months), and monthly thereafter, until was achieving clinically and radiological healing. The functional outcome was evaluated using the Constant score, and DASH score in the last follow-up.
RESULTS: The mean Constant Score was 95.5±5.2 points (range, 85-100), with a mean DASH score of 3.3±4.4 points (range, 0-12.5). The mean time to clinical healing was10.3±3.1 weeks (range, 8-16), and the mean time to radiological healing was 13.6±2.6 weeks (range, 12-20). There were no major complications. There were 5 minor complications without clinical impact: 2 coracoclavicular calcifications, 1 hypertrophic scar, 1 patient with discomfort due to the device, and 1 superficial wound infection. All patients returned their previous activity.